background image

 

 

ENGLISH .......................................................................... 1

 

SVENSKA ...................................................................... 14

 

NEDERLANDS ................................................................  25

 

DANSK .......................................................................... 37

 

WARRANTY ...................................................................  50 

TEMPLATES ...................................................................  51 

© 2008-2015 Tru-Test Limited 

All product names and brand names in this document are trademarks or registered trademarks of their 
respective holders. 
No part of this publication may be photocopied, reproduced, stored in a retrieval system, or transmitted in 
any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior 
written permission of Tru-Test Limited. Product specifications may change without prior notice.  
For more information on other quality Tru-Test Group brands and products, visit www.tru-test.com. 
Tru-Test Limited 
25 Carbine Road 
Mt Wellington 
Auckland 1060 
New Zealand 

Postal address:

 

P O Box 51078 
Pakuranga 
Auckland 2140 
New Zealand 

Tru-Test Ltd thanks the International Electrotechnical Commission (IEC) for permission to reproduce 
Information from its International Publication 60335-2-76 ed.2.

2

 (20

13

). All such extracts are copyright of 

IEC, Geneva, Switzerland. All rights reserved. Further information on the IEC is available from www.iec.ch. 
IEC has no responsibility for the placement and context in which the extracts and contents are reproduced 
by the author, nor is IEC in any way responsible for the other content or accuracy therein. 
829767 Issue 1 (to be supplied 

to Continental Europe [only] 

with 816260)  08/2015 

ENGLISH 

Electric fencing and your energizer 

Congratulations on the purchase of your energizer. This product has 
been constructed using the latest technology and construction 
techniques. It has been engineered to give superior performance and 
many years of service. 
It is important to read these instructions carefully and thoroughly. They 
contain important safety information and will assist you in ensuring that 
your electric fencing system gives maximum performance and reliability. 

 

How does an electric fence work? 

An electric fence system comprises an energizer and an insulated fence. 
The energizer puts very short pulses of electricity onto the fence line. 
These pulses have a high voltage, but are of very short duration (less 
than 3/10,000ths of a second). However, a shock from an electric fence 
pulse is very uncomfortable and animals quickly learn to respect electric 
fences.  An electric fence is not only a physical barrier, but is also a 
strong psychological barrier. 

 

What are the benefits of an electric fence? 

An electric fence has many benefits over conventional fencing: 

 

Requires less labour and materials to construct. 

 

Flexibility to change or add paddocks when required.  The use of 
strip grazing techniques can allow temporary fencing to be quickly 
and easily erected or removed. 

 

Controls a broader range of animals. 

 

Minimises damage to expensive livestock when compared with 
other fencing mechanisms, for example barbed wire. 

Models covered by this manual 

This manual covers various energizer models: 

12000i, X12i, 
412i 

12 J energizers. These energizers have an LCD display, 
an earth monitoring feature and remote control 
capabilities. 

6000i, X6i, 406i 

6 J energizers. These energizers have an LCD display, an 
earth monitoring feature and remote control 
capabilities.  

6000i-EU, X6i-EU, 
406i-EU 

6 J energizers sold in Europe. These energizers have an 
LCD display, an earth monitoring feature and remote 
control capabilities. If the energizer detects a sudden 
increase in the load on the fence, a warning is issued. 
The energizer may increase its output power to more 
effectively energise the fence. 

6000, X6, 406 

6 J energizers. 

6000-EU, X6-EU, 
406-EU 

6 J energizers sold in Europe. If the energizer detects a 
sudden increase in the load on the fence, a warning is 
issued. The energizer may increase its output power to 
more effectively energise the fence. 

Note:

 The energizers listed here may not be available in all markets. 

Key to symbols on the energizer 

 

Fence earth terminal. Connect the fence earth terminal to the 
energizer earth system. 

 

Fence earth monitor terminal 

(12000i,  X12i, 412i, 6000i, 6000i-

EU, X6i, X6i-EU, 406i and 406i-EU energizers only).

 Connect the 

fence earth monitor terminal to a separate earth rod. See 

Earth 

monitoring

 on page 5. 

 

Fence half voltage terminal. For use in areas with poor earthing, 
see 

Bi-polar installation

 on page 8 or in areas where a limit of 5 kV 

fence voltage is desirable (e.g. where fire risk is present or where 
there is a risk of someone touching the fence), see 

Reducing the 

fence voltage output

 on page 9. Connect the fence half voltage 

terminal to the fence. 

 

Fence full voltage terminal. Connect the fence full voltage terminal 
to the fence. 

 

Risk of electric shock! This energizer should be opened or repaired 
only by qualified personnel. 

 

 

Read full instructions before use. 

Summary of Contents for Unigizer 12000i

Page 1: ...ences An electric fence is not only a physical barrier but is also a strong psychological barrier What are the benefits of an electric fence An electric fence has many benefits over conventional fencing Requires less labour and materials to construct Flexibility to change or add paddocks when required The use of strip grazing techniques can allow temporary fencing to be quickly and easily erected ...

Page 2: ... the risk of electric shock the energizer s power adaptor may have a polarized plug one blade is wider than the other This plug will fit in a polarized outlet one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way Switch the energizer off before installation or per...

Page 3: ...lip to the positive terminal of the battery and the black clip to its negative terminal Note If the energizer is to be used as part of a permanent outdoor installation such as a solar installation the battery lead clips should be replaced by permanent battery connectors To remove the battery leads 1 Remove the clips from the battery terminals 2 Hold the battery lead by the rubber sleeve at the end...

Page 4: ...e energizer with mains line power if it is being installed outdoors USA Canada Refer to Important safety instructions for Class 2 power units USA Canada only on page 11 To install the energizer as part of a solar installation 1 Select a suitable installation site See Selecting a site for the installation on page 3 For solar installations it is also important to select a site where the solar panel ...

Page 5: ...egments are illuminated at each pulse the output voltage is approximately 8 kV 8000 V Red Green 1 2 3 4 5 6 7 8 9 10 kV Note If ten Indicator light segments are illuminated the output voltage may be more than 10 kV 10 000 V If you see only red lights at each pulse and no green lights your fence line is very heavily loaded and you will need to look for faults on the fence line See Frequently asked ...

Page 6: ...slow speed 2 5 seconds between pulses and the fence is live Lights Input supply voltage Battery only installation Above 17 0 V Abnormal conditions check battery and connections 12 6 V 17 0 V Full battery charge voltage 80 100 No action required or 12 3 12 6 V 12 0 12 3 V Medium battery charge voltage 50 80 No action required 11 7 12 0 V Low battery charge voltage 20 50 Monitor battery voltage Rech...

Page 7: ...Ah Warning 12 V rechargeable batteries must be used Battery management Warning Batteries contain harmful chemicals and when used incorrectly may cause injury Observe the guidelines for battery care maintenance and safety in this manual and in the documentation supplied with your battery Battery charging Warning Do not attempt to recharge a non rechargeable battery When recharging a battery ensure ...

Page 8: ... fence system comprises the following elements An energizer An earth system This comprises a number of metal rods inserted into the ground which are connected to the Fence earth terminal on the energizer Insulated underground cables Electric fence wire coated in insulated plastic suitable for use underground or going through walls Used to connect the energizer to the earth and fence An insulated f...

Page 9: ...er firmly setting the footed strainer in the ground dig in the stay block just below ground level at a distance to ensure the angle stay will be held snugly in position The stay can be levered into position with a spade All live system Fence return system Horizontal stay Suitable for field gate high tension strainer Very simple to erect and most suitable as a high tension strainer excellent in are...

Page 10: ...rier not less than 1 5 m 5 high intended to prevent inadvertent contact with the pulsed conductors of the electric fence Physical barriers are typically constructed from vertical sheeting rigid vertical bars rigid mesh rods or chainwire mesh Requirements for electric animal fences Electric animal fences and their ancillary equipment shall be installed operated and maintained in a manner that minim...

Page 11: ...onnected to the electric animal fence circuit provides a degree of isolation between the fence circuit and the supply mains equivalent to that provided by the energizer Protection from the weather shall be provided for the ancillary equipment unless this equipment is certified by the manufacturer as being suitable for use outdoors and is of a type with a minimum degree of protection IPX4 Important...

Page 12: ...d energy in the battery If This means that 6000i EU X6i EU 406i EU 6000 EU X6 EU and 406 EU energizers only The warning light is flashing and a warning buzzer is sounding The energizer has detected a sudden increase in the load on the fence Switch the energizer off locate and remedy fault then turn the energizer on again For example this may occur if a cutout switch is closed connecting a heavily ...

Page 13: ...D and or the symbol below Product specifications 6 J models 12 J models Power supply 12 V battery or approved power adaptor 100 120 V or 100 240 V Power consumption using a power adaptor 10 W 15 W Current consumption using a 12 V rechargeable battery Battery Test 410 mA 700 mA Slow Speed Day Fast Speed Night 410 mA day 650 mA night or 530 mA 24 hour average 700 mA day 1100 mA night or 900 mA 24 ho...

Page 14: ...tet Stängslets jordningsuttag Anslut stängslets jordningsuttag till aggregatets jordningssystem Stängslets jordningsövervakningsuttag endast aggregat 12000i X12i 412i 6000i 6000i EU X6i X6i EU 406i och 406i EU Anslut stängslets jordningsövervakningsuttag till en separat jordningsstake Se Jordningsövervakning på sidan 18 Stängslets halvspänningsuttag För användning i områden med dålig jordning se B...

Page 15: ...lutning till nät ledningsström och en uppsättning batteristift för anslutning till ett batteri Innan en strömadapter eller batteristift ansluts säkerställ att aggregatets väljarbrytare är inställd på Av För att använda strömadaptern 1 Anslut strömadaptern till strömingångsuttaget på baksidan av aggregatet 2 Anslut strömadaptern till ett lämpligt nät ledningsuttag och försäkra dig om att det finns ...

Page 16: ...rdningssystem 4 Endast aggregat 12000i X12i 412i 6000i 6000i EU X6i X6i EU 406i och 406i EU Om jordningsövervakning önskas anslut stängslets jordningsövervakningsuttag svart till en separat jordningsstake För mer information se Jordningsövervakning på sidan 18 5 Anslut stängslets helspänningsuttag rött eller stängslets halvspänningsuttag gult till stängslet 6 Anslut aggregatet till batteriet med d...

Page 17: ...r på natten När denna inställning används drivs aggregatet med full energi Denna inställning är för djur som är aktiva på natten och är ett lämpligt sätt att spara på batteriet när ett batteri används för att ge energi åt aggregatet Snabb hastighet dag Långsam hastighet natt Aggregatet drivs med snabb hastighet 1 5 sekunder mellan pulser på dagen och långsam hastighet 2 5 sekunder mellan pulser på...

Page 18: ...g Se till att isoleringen skalas tillbaka för att få god kontakt mellan tråden och jordledningsstaven Övervakning av jordningen Om den första indikatorlampan lyser permanent indikerar detta att jordspänningen är över 0 8 kV och att bättre jordning kan vara till en fördel Använd antingen fler jordningsstavar eller hitta en bättre plats för aggregatets jordledningssystem De små siffrorna på LCD disp...

Page 19: ...ler inget solljus Den tar med olika solpanels och regulatortyper i beräkningen som skulle kunna användas i solpanelsinstallationen För mer detaljerad information se www tru test com Väljarom kopplarens position Ström som krävs ungefärlig Minsta batterikapacitet 80 urladdning 6 J modeller 12 J modeller 6 J modeller 12 J modeller 410 mA 700 mA 110 Ah 190 Ah 410 mA dag 650 mA natt 530 mA 24 timmars g...

Page 20: ... återaktiveras efter ett strömavbrott även om det stängdes av av den fjärrkontrollerade handenheten innan strömavbrottet Stängslet måste alltid anses vara strömförande oavsett aggregatets omkopplarposition eller fjärrkontrollens status Om du arbetar på ett stängselavsnitt isolera avsnittet med en strömbrytare eller koppla bort aggregatet från strömkällan Att bygga ett permanent elstängsel Komponen...

Page 21: ...ttag gult används överskrider stängslets spänning inte 5 kV men utgångsströmmen förblir densamma Stängselutföranden Stängsel kan konstrueras så att de passar boskapstypen och tillgängliga material Rådgör med återförsäljaren om vilket utförande som passar dina behov En del förslag på stängselkonfigurationer anges nedan Nötboskap och hästar 10 15 m mellanrum enbart stolpar 15 20 m mellanrum med mell...

Page 22: ...r bättre sikt krävs t ex hästar Ett exempel på ett temporärt stängsel visas nedan Säkerhetsåtgärder Definitioner av specialuttryck Elstängselaggregat En apparat som periodvis avger spänningsimpulser till ett stängsel som är anslutet till det Stängsel En barriär för djur eller i säkerhetssyfte bestående av en eller flera ledare såsom metalltrådar stavar eller räcken Elstängsel En barriär som innehå...

Page 23: ...tt elektriskt djurstängsel korsar en allmän stig ska en ej elektrifierad grind byggas in i det elstängslet vid den punkten eller också ska en korsning anordnas med hjälp av en stätta Vid en sådan korsning ska angränsande elektrifierade trådar vara försedda med varningsskyltar om elstängsel Alla delar av ett elstängsel som installeras längs en allmän väg eller stig ska identifieras med täta mellanr...

Page 24: ...ayen blinkar 1 0 kV Stängslets spänning är under 1 000 V Det har uppstått ett allvarligt fel i stängselledningen Se Hur hittar jag fel i Vanliga frågor Felsökning på sidan 23 Endast aggregat 12000i X12i 412i 6000i 6000i EU X6i X6i EU 406i och 406i EU Den första röda indikatorlampan lyser permanent Jordningsövervakningsspänningen är för hög Använd jordningsövervakningsfunktionen för att övervaka jo...

Page 25: ...r garantie wordt geclaimd stuur dit product dan met een bewijs van aankoop naar de zaak waar u het heeft gekocht Details van garantieperiodes en andere van toepassing zijnde voorwaarden zijn verkrijgbaar bij de zaak waar u het product heeft gekocht of bij www tru test com N B Er wordt geen aansprakelijkheid aanvaard voor ongevallen of schade die het gevolg zijn van manipulaties aan dan wel verande...

Page 26: ...51 130 mm 5 1 8 216 mm 8 1 2 6 J Unigizer ...

Page 27: ...52 170 mm 6 3 4 12 J Unigizer 225 mm 8 7 8 222 mm 8 3 4 ...

Reviews: