True Blue Power
Revision 1, June 15, 2018
6
Prepare the panel cutout as shown in Figures 3.4, 3.5, 3.6, 3.7, or 3.8 per the selected mounting option.
•
For Rear Mount (rectangular) and Instrument Mount Installations countersinks in the panel for flat
head screws are optional. However, flat head screws are provided for flush appearance. For Front
and Rear Decorative Bezel Installations, countersinks in the panel are required.
•
For Rear Mount Installations:
Mounting screws length MUST be between (PT +0.150”) and (PT +0.210”). [PT = panel thickness]
Mounting screws p
rovided with the unit are 0.24” and 0.31”. (accommodates 0.030” to 0.160” PT)
For PT greater than 0.125, the USB connector will be below the surface of the panel (below flush).
•
For Front Mount Installations: Minimum panel thickness is 0.04”. Maximum panel thickness is 0.20”.
•
For Rear Mount Installation with Decorative Bezel: Panel thickness greater than 0.065 will cause the
USB connector to be below the surface of the bezel (below flush).
USBT202 Outline Drawing
(dual port, rear input version shown)
USBT201 Outline Drawing
(single port, rear input version shown)
Figure 3.2
Figure 3.3