Page 14
Calibration Procedures
455 Calibration
Enter Calibration Mode by holding the
Up
and
Down
keys while inserting the safety key
In message center window displayed: Press Start to Calibrate
NOTE:
In Calibration mode, it is possible to check if the speed sensor is reading all the front roller
magnets: the Met light will light when a magnet is in front of the sensor. Speed must be less than 1 mph.
Press
Start/Reset
to begin calibration
Treadmill will elevate and speed up/slow down. Wait for belt to stop.
Message center window will display: Successful, or will indicate error area.
Remove and re-insert safety key. Check operation of treadmill.
Support Services 800-883-8783
Mon-Fri 8:30am-5:00pm Central Time Zone
Fax: 636-272-7148
Summary of Contents for 455 Pediatric
Page 24: ...Page 22 Page 22 455 Wiring Diagram ...
Page 27: ......