Proprietary & Confidential
TRUE Fitness Technology, Inc.
Proprietary & Confidential
TRUE Fitness Technology, Inc.
Upper
Board
Smart
Board
Lower
Board
Drive
Motor
Feed Back
Command Signal
The new TCS Series treads with the smart card system utilize a
digital signal for both command and feedback. This signal cannot be
tested with normal field equipment. Diagnostics must be done using the
status lights on both the lower control board and smart card.
2. DC DRIVE WITH SMART CARD INTERFACE
(
TES900, TLC900
and TPS850)
This system is basically the same as the above AC smart card
system; however, no motor transmit and receive LEDs are lit on
the DC smart card.
3. DC DRIVE
(
All TPS series except TPS850, Z5 series
)
This system is the same as all our traditional DC drive systems
SYMPTOM GUIDE
A.
DRIVE SYSTEM OVERVIEW
In this summary we are going to cover basic troubleshooting
techniques used in the industry to diagnose and repair True Fitness
treadmills more quickly and efficiently. Current True treadmills use 3
types of drive system:
1. AC DRIVE WITH SMART CARD INTERFACE
(
TCS Series and
TLC1100).
9