GDM HST02
TEC_TM_158 | REV. A | EN
06/28/2022
Page 21 of 28
www.truemfg.com
L A E C O N T R O L L E G E N D
Info/Set Point
Manual Activation/
Up Arrow
Manual Defrost/
Down Arrow
Stand-By/
Cancel
Compressor Running
Activation of 2
nd
Parameter Set
Alarm
Cabinet in Defrost
Evaporator Fan Running
Electronic Temperature Control (cont.)
Change Defrost Intervals
The defrost interval is the duration between defrost cycles,
NOTE:
The defrost interval
can only be changed
if the
defrost mode parameter
dFm
is set for
tim
or
Fro
.
1.
Press and hold both info
and cancel
until the
display shows
hSt
.
2.
Press the up arrow
until the display shows
dFt
.
3.
Press and hold info until the display shows the current
defrost interval time.
DO NOT RELEASE THE BUTTON!
4.
While holding info, the up or down
arrows to adjust
the setting.
5.
Release all buttons and wait for the control to display the
current cabinet temperature.
Change Display Readout
The display can show the temperature in either Fahrenheit or
Celsius.
Press cancel
to cycle through the display readout
options.
•
°F
: Fahrenheit (no decimal)
•
1°C
: Celsius (0.1 precision)
•
2°C
: Celsius (no decimal)
Celsius
Celsius (0.1 precision)
Fahrenheit