background image

INSTALLATION 
AND OPERATING 
INSTRUCTIONS

SAFETY NOTICE:  If this stove 
is not properly installed, a house 
fi re may result.  For your safety, 
follow the installation  instructions.  
 Contact local building or fi re officials 
about restrictions and installation 
inspection requirements in your 
area.

121211-20 TN19  5055.551

TESTED and LISTED to CAN/ULC S627 
AND UL 1482
Meets the Environmental Protection 
Agency's July 1990 Particulate Emission 
Standards

IMPORTANT:

THESE INSTRUCTIONS ARE TO 
REMAIN WITH THE HOMEOWNER
SAVE THESE INSTRUCTIONS

MODEL: TN19
SERIES: A

Summary of Contents for TN19

Page 1: ...Contactlocalbuildingorfireofficials about restrictions and installation inspection requirements in your area 121211 20 TN19 5055 551 TESTED and LISTED to CAN ULC S627 AND UL 1482 Meets the Environmen...

Page 2: ...moval 6 Stove Dimensions 7 Minimum Clearance to Combustibles 7 Minimum Clearance to Combustibles with Optional Side Shields 8 Residential 9 Installation 9 Crate Removal 9 Clearances 9 Chimney and Conn...

Page 3: ...mbustion and dry well seasoned wood and therefore relatively clean pipes and chimney On the other hand a black greasy deposit that is difficult to remove is a result of wet and green wood and too slow...

Page 4: ...of dry seasoned wood and ample combustion air will help to minimize the buildup Chimney Fires The result of excessive creosote buildup is a chimney fire Chimney fires are dangerous Chimney inside tem...

Page 5: ...igniting in five minutes it is soaked and should not be burned Lighting for the First Time Remove the retaing clip on the front of the baffle before lighting for the first time Curing of the Paint Fin...

Page 6: ...r starting or preheating fresh fuel loads DO NOT OVERFIRE THIS HEATER Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater and ch...

Page 7: ...7 8 26 1 4 26 1 4 19 7 8 19 7 8 6 1 2 6 1 2 FIG 1 16 1 2 10 30 20 6 1 2 13 30 20 22 1 2 22 1 2 12 12 12 12 16 1 2 10 37 27 29 1 2 19 19 Double Wall Connector Mobile Home Single Wall Connector Resident...

Page 8: ...26 16 17 1 2 7 7 23 1 2 13 13 16 1 2 10 30 20 16 Double Wall Connector Mobile Home Alcove Min Height 7 1 2 Max Depth 3 Double Wall Connector Residential Single Wall Connector Residential Minimum Clea...

Page 9: ...othechimneyconnectormanu facturer s installation requirements Single Wall Connector Smoke pipe must be asshortandstraightaspossible usesixinchdiameter 24 gauge black pipe that is clean and in new cond...

Page 10: ...7 2 1m Ceiling Height Non combustible floor protector 48 1219 mm Hooded vent or 90 elbow turned down Ensure that the Masonry chimney meets all National Fire Protection Association and local building c...

Page 11: ...024 in 0 61 mm in thickness having two 1 in 25 4 mm air chan nels separated from combustibles by a minimum of 6 in 152 mm of glass fiber insulation Opening shall be covered and thimble supported with...

Page 12: ...lowing conditions have been met DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE DO NOT INSTALL IN A SLEEPING ROOM Outside air supply must be used for Mobile Home instalations see...

Page 13: ...trial Chimney Model Excel Ultra Black 4 Selkirk Metalbestos Model DS 8 Simpson Dura Vent Model DVL B As well as one of the following compatible chimney systems All parts 6 CANADA ONLY Security Pro Jet...

Page 14: ...dislodging of the air duct Outside air may also be ducted from outside through the 4 diameter hole in the rear of the pedestal enclosure Note This unit is not designed to be operated with the firing d...

Page 15: ...te from the rear shield on the stove Fig 8 2 Using the same 4 screws place the blower into the opening in the rear shield with the blower outlet pointing up Fig 8 3 Tighten the screws Blower Operation...

Page 16: ...ting tightly against screws Fig 11 3 Align holes in rear of side shield with holes in firebox side and secure tightly with screws previously removed Firebrick Installation The package contains 20 full...

Page 17: ...essive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overn...

Page 18: ...Tube Set 4pcs TRNO 50001101 3 Door CastingAssy c w Handle TRNO DRBK 4 Replacement Glass c w gasket TRNO 7025 5 Door Gasket TN19 DGKIT 6 Glass Clamps 4 pc 7608 7 Firebrick Set 9 x4 1 2 x1 1 4 20pcs TRN...

Page 19: ...LORSQUE LA PORTE D ALIMENTATION EST FERM E OUVREZ SEULEMENT POUR ALIMENTER LE FEU GARDEZ LES MEUBLES ET AUTRES MAT RIAUX COMBUSTIBLES BIEN LOI GN S DU PO LE REMPLACES LA VITRE AVEC UNIQUEMENT DE LA V...

Page 20: ...20 TN19 121211 20 PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan BC V9L 6V8 Phone 250 748 1184 Web site http www pacificenergy net...