Page 1: ...TRUE SOURCE User Manual Air Pump Model TS 60XX E2 X 0 9 A Z UM 60XX EN V1 1 Date 20210105 Copyright by TRUE SOURCE Technology Co Ltd ...

Page 2: ...tents 7 4 Product Features 8 5 Product Description 9 6 Installation 10 7 Operating Principle 11 8 Air Pump Settings Contents 11 9 Routine Maintenance and Cleaning 15 10 Storage 15 11 Troubleshooting 16 12 Technical Specifications 18 13 EMC Table 19 14 Warranty 25 15 Warranty Card 26 16 Contact 27 ...

Page 3: ... ISO 7010 W012 Warning electricity ISO 15223 1 2016 Ref no 5 1 7 Serial number ISO 15223 1 2016 Ref no 5 1 6 Catalogue number ISO 15223 1 2016 Ref no 5 1 9 Distributor ISO 15223 1 2016 Ref no 5 1 2 Authorized representative in the European Community ISO 15223 1 2016 Ref no 5 7 10 Unique Device Identifier ISO 15223 1 2016 Ref no 5 2 7 Non sterile IEC 60417 5333 TYPE BF APPLIED PART ISO 15223 1 2016...

Page 4: ...ctrical and electronic equipment IEC 60417 5008 OFF power IEC 60417 5007 ON power No AP APG Non applicable to the presence of flammable anesthetics or a high concentration of oxygen in the environment AP or APG IP21 IEC 60529 Protected against solid foreign objects of 12 5 mm and greater Protection against vertically falling water drops Label content template Located at back of the air pump ...

Page 5: ...r Users to be considered A Installation personnel only by manufacturer trained and authorized technician for both device and mattress B Cleaning personnel by professional healthcare personnel general personnel or lay user C Maintenance repair personnel only by manufacturer trained and authorize technician D Operating personnel Professional healthcare personnel general personnel or lay user which m...

Page 6: ...asily disconnected and where unlikely to be in contact with children or pets The age of the expected object is 20 60 years old and the expected load is defined according to different mattress types and the expected maximum is 250Kg When you need to dispose of your products please follow the guidance of your local authority or follow national requirements This medical device can be used in home use...

Page 7: ...he power to the unit please disconnect the power cord from the AC outlet The AC outlet shall be readily available and accessible For plug in equipment the power outlet socket must be located near the equipment and must be easily accessible The air pump must be placed on the foot end of the nursing bed not on the head Turn off the power switch on the side panel and unplug the power cord to ensure c...

Page 8: ...r shock absorption the deflation Pump inside is equipped with a specially designed suspension shock absorption system and a foot mat is provided outside the unit in order to reduce the shock 5 The compact size feature The system is of a compact size making it easy for placement and storage and taking into account the streamlined system appearance and practicality 6 The cotton air filter is to be r...

Page 9: ...9 5 Product description 1 Control panel 2 Front Case 3 Quick coupling 4 AC Inlet 5 Off On Power Switch 6 Rear Case A Bed Hooks B Fuses T1A 250V C Label D Air Filter Air Pump ...

Page 10: ... starts to enter the hose in a few seconds Step 5 Select a setting according to the patient s comfort setting or Keep the initial value Step 6 See Air Pump Settings Contents to select setting for your need Step 7 Please wait until all the air cells are inflated by at least 2 3 of their volume approx 10mmHg or for 30 minutes before the user is allowed to lie on the mattress Note Ensure that the pat...

Page 11: ... the distribution of body pressure 8 Air Pump Settings Contents Representative Model TS 6000 Button Function Area 1 mmHg Display Where a dot appears after a reading this means that the system to be reset adjusted When there is no dot the reading is a display of the pressure being supplied to air cells which are being inflated 2 Comfort Setting Initial setting in 30mmHg In Alternating Mode Soft 20m...

Page 12: ...e if the mattress is too soft This can harden the mattress in the quickest way for easy nursing However after 30 minutes the unit will forcefully resume the setting before the button is pressed in order to protect the patient from the risk of developing pressure ulcers because the mattress becomes too hard Press the button when necessary 6 Lock Unlock Button The button can lock the existing set st...

Page 13: ...cator is on this means that the Nursing Button is activated However after 30 minutes the unit will forcefully resume the setting before the button is pressed in order to protect the patient from the risk of developing pressure ulcers because the mattress becomes too hard d Lock Unlock Indicate When the orange indicator is on this means that the Lock Function is activated When it is off this means ...

Page 14: ...ode O O O O O Alternating cycle time fixed fixed fixed fixed fixed fixed Static Mode O O O O O Auto Firm Mode Nursing O O O O O Auto Dual Mode Seat Mode other X O O X X Low Pressure Alarm O O O O O Power Failure Alarm O O O O O Service Alarm O O O O O Lock Unlock O O O O O ON Stand By X X O O X Stable Base X X X O O Note O means support function X means not support function ...

Page 15: ...ike substance from entering the unit and resulting in the deterioration of internal pipes and the need for frequent replacement of the air cotton filter Suggestion An air purifier can also be used to maintain the air quality 10 Storage How to store the Air Pump 1 It is necessary to turn off the power switch in side panel unplug the power cord 2 Disconnect the Air Pump and the power cord disconnect...

Page 16: ...witched to ON 1 2 If not switch to ON 1 3 Check if the fuse has burnt out or not properly installed 1 3 Turn off the power and check the fuse 2 Air Pump is working but mattress is not inflating 2 1 Check if air comes out of the air Pump and if the connector is properly connected 2 1 If the unit operates normally but no air comes out it is possible that the air Pump has something wrong inside and n...

Page 17: ... 5 Check if the air cotton filter is heavily soiled and the air is blocked 2 5 Replace the filter if it is heavily soiled 3 Bottom in contact with the overlay 3 1 Check Comfort setting 3 1 Increase Setting Value 3 2 Check if air leaks from the mattress 3 2 Replace the air cells if damaged 3 3 Check if the air cotton filter is heavily soiled and the air is blocked 3 3 Replace the filter if it is he...

Page 18: ...ided together If in doubt please contact the manufacturer for more information 4 cells mattress loading weight 30 120kg 5 cells mattress loading weight 30 150kg 6 cells mattress loading weight 30 180kg 8 cells mattress loading weight 30 200kg 30 250kg optional Environment Condition Usage Transport Storage Temperature 5 C 40 C 10 C 45 C 5 C 45 C Humidity 15 to 93 10 to 93 10 to 80 Atmospheric Press...

Page 19: ...e RF emissions CISPR 11 The model TS 6000 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 The model TS 6000 is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that...

Page 20: ...W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distanced in meters m can be estimated using the equation applicable to the frequency...

Page 21: ...wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines 2 kV for power supply lines 1 kV for input output lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV line s to line...

Page 22: ...00 4 8 3 A m 3 A m NOTE UT is the a c mains voltage prior to application of the test level Guidance and manufacturer s declaration electromagnetic immunity The model TS 6000 is intended for use in the electromagnetic environment specified below The customer or the user of the model TS 6000 should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Elec...

Page 23: ...frequency of the transmitter Recommended separation distance d 1 2 P d 1 2 P 80 MHz to 800 MHz d 2 3 P 800 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be les...

Page 24: ...adio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the model TS 6000 is used exceeds the applicable RF compliance level above the model TS 6000 should be observed to verify nor...

Page 25: ...ply Only function failure repair is covered during the warranty period The warranty does not include general maintenance e g replacement of the cotton filter cleaning setting adjustment or component renewal The warranty does not cover maintenance conducted by opening the air Pump without authorization careless dropping or use of the product other than for its intended purpose and repair of such is...

Page 26: ...26 15 Warranty Card Warranty Card Model TS 60XX E2 Air Pump X 0 9 A Z Purchase date _______ _____ _____ Distributor Signatures ...

Page 27: ...RCE TECHNOLOGY CO LTD 4F No 3 Lane 130 Minquan Road Xindian District New Taipei City 23141 TAIWAN R O C Obelis s a Boulevard Général Wahis 53 1030 Brussels BELGIUM Tel 32 2 732 59 54 Fax 32 2 732 60 03 E Mail mail obelis net ...