THIS WARRANTY ONLY APPLIES TO UNITS SHIPPED FROM TRUE’S MANUFACTURING FACILITIES AFTER JULY 1, 2014.

THREE YEAR PARTS & LABOR WARRANTY

ADDITIONAL TWO YEAR  COMPRESSOR WARRANTY

404A/134A  COMPRESSOR WARRANTY

WARRANTY CLAIMS

WHAT IS NOT COVERED BY THIS WARRANTY

TRUE warrants to the original purchaser of every new TRUE refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal and 
proper use and maintenance service as specified by TRUE and upon proper installation and start-up in accordance with the instruction packet supplied with each TRUE unit.  TRUE’s 
obligation under this warranty is limited to a period of three (3) years from the date of original installation or 39 months after shipment date from TRUE, whichever occurs first.
Any part covered under this warranty that are determined by TRUE to have been defective within three (3) years of original installation or thirty-nine (39) months after shipment date 
from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or assemblies.  The labor warranty shall include standard straight 
time labor charges only and reasonable travel time, as determined by TRUE.
Warranty does not cover standard wear parts which include door gaskets, incandescent bulbs or fluorescent bulbs.  Warranty also does not cover issues caused by improper installation 
or lack of basic preventative maintenance which includes regular cleaning of condenser coils.

In addition to the Three (3) year warranty stated above, TRUE warrants its hermetically and semi-hermetically sealed compressor to be free from defects in both material and workman-
ship under normal and proper use and maintenance service for a period of two (2) additional years from the date of original installation but not to exceed five (5) years and three (3) 
months after shipment from the manufacturer.
Compressors determined by TRUE to have been defective within this extended time period will, at TRUE’s option, be either repaired or replaced with a compressor or compressor parts 
of similar design and capacity.
The two (2) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the compressor and does not apply to any other parts or components, 
including, but not limited to: cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting equipment, fan assembly or any other electrical component, etcetera.

The two year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:
1. This system contains R404A or R134A refrigerant and polyol ester lubricant.  The polyol ester lubricant has rapid moisture absorbing qualities.  If long exposure to 
the ambient conditions occur, the lubricant must be removed and replaced with new.  For oil amounts and specifications please call TRUE technical service department  
(855-372-1368).  Failure to comply with recommended lubricant specification will void the compressor warranty.
2. Drier replacement is very important and must be changed when a system is opened for servicing.  A drier using XH-7 desiccant or an exact replacement solid core drier 
must be used.  The new drier must also be the same capacity as the drier being replaced.
3. Micron level vacuums must be achieved to insure low moisture levels in the system.  500 microns or lower must be obtained.

All claims for labor or parts must be made directly through TRUE.  All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of instal-
lation, and all pertinent information supporting the existence of the alleged defect.
 In case of warranty compressor, the compressor model tag must be returned to TRUE along with above listed information.
Any action or breach of these warranty provisions must be commenced within one (1) year after that cause of action has occurred.

TRUE’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below.  This warranty neither assumes nor authorizes any 
person to assume obligations other than those expressly covered by this warranty.
NO CONSEQUENTIAL DAMAGES.  TRUE IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING 
WITHOUT LIMITATION, LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF REFRIGERATION FAILURE.
WARRANTY IS NOT TRANSFERABLE.  This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered.  ANY SUCH ASSIGNMENT OR 
TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY 
OR FITNESS FOR A PARTICULAR PURPOSE.
IMPROPER USAGE.  TRUE ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER DAMAGES RESULTING FROM IMPROPER 
USAGE OR INSTALLATION OR FAILURE TO CLEAN AND/OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET PROVIDED WITH THE UNIT.
RELOCATION OF CABINET FOR REPAIR: True is not responsible for the cost to move a cabinet for any reason from its position of operation on the customer’s premises to make a 
warranty repair. 
RESIDENTIAL APPLICATIONS:  TRUE assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non-commercial or residential 
applications.
ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD.  TRUE is not responsible for the repair or 
replacement of any parts that TRUE determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, 
flood, or act of God.
IMPROPER ELECTRICAL CONNECTIONS.  TRUE IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM 
INCORRECT SUPPLY VOLTAGE, THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR UNSTABLE SUPPLY VOLTAGE. 

NO IMPLIED WARRANTY OF MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE:  THERE ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE THREE (3) YEAR PARTS & LABOR 
WARRANTY AND THE ADDITIONAL TWO (2) YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE.  THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER 
WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  THERE ARE NO WARRANTIES WHICH EXTEND 
BEYOND THE DESCRIPTION ON THE FACE HEREOF.
OUTSIDE U.S./Canada:  This warranty does not apply to, and TRUE is not responsible for, any warranty claims made on products sold or used outside the United States/Canada.  
This warranty only applies to units shipped from True’s manufacturing facilities after July 1, 2014.

WARRANTY INFORMATION (U.S.A & CANADA ONLY!)

T

RUE

 

R

EFRIGERATION

MADE IN

SINCE 1945

U.S.A.

®

Summary of Contents for GDIM

Page 1: ...ALLATION MANUAL INSTALLATION MANUAL gdim glass door ice merchandisers TABLE OF CONTENTS 975541 LM 6 15 SAFETY INFORMATION Safety Precautions 1 Proper Disposal Connecting Electricity Adapter Plugs 2 IN...

Page 2: ...tions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion due to punctur...

Page 3: ...OUNDED The power cord from this appliance is equipped with a grounding plug which minimizes the possibility of electric shock hazard Have the wall outlet and circuit checked by a qualified electrician...

Page 4: ...ges 4 6 Do not throw the bracket or blocks away For future cabinet movement the bracket and blocks will need to be installed so the glass door does not receive any damage See image for bracket and shi...

Page 5: ...8 8 8 5 20 14 12 10 10 8 8 8 6 6 6 5 5 25 12 10 10 8 8 6 6 6 6 5 4 4 30 12 10 8 8 6 6 6 6 5 4 4 3 35 10 10 8 6 6 6 5 5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4...

Page 6: ...stall the desired number of shims making sure the slot of the shim is in contact with the threaded stem of the castor See image 2 C If more than one shim is used turn the slot at a 90 angle so they ar...

Page 7: ...f the cooler Level cabinet STEP 3 Draw an outline on the base on the floor STEP 4 Raise and block the front side of the cabinet STEP 5 Apply a bead of NSF Approved Sealant see list below to floor on h...

Page 8: ...Should it ever become necessary to replace temperature control be sure it is ordered from your TRUE dealer or recommended service agent D Good air flow in your TRUE unit is critical Be careful to loa...

Page 9: ...e evaporator coil is reached 3 The temperature control may cycle the compressor and evaporator fan s on and off together a The temperature control is sensing the air temperature b The temperature cont...

Page 10: ...making adjustment measure temperature during three cycles before adjusting again NOTE Only adjust the screw small flathead on the face of the control next to the cam See Figure 3 Follow the Altitude...

Page 11: ...which wire is on which spade terminal STEP 4 Pull out gently from cabinet NOTE Mechanical temperature controllers are affected when functioning at high altitude The cut in and cut out temperatures wil...

Page 12: ...truemfg com O 9 8 7 6 5 4 3 2 1 2 O 9 8 7 5 4 3 2 1 CUT OUT CUT IN COLDER BUL NO CHART CCW Adjustment based on 360 complete turn Height 2000 42 3000 78 4000 114 5000 150 6000 186 7000 222 8000 258 900...

Page 13: ...RATION FOR UNITS WITH MECHANICAL CONTROL RECOMMENDED DEFROST SETTINGS TRUE Manufacturing has factory set your defrost time clock to a recommended time and duration defrost scenario All refrigeration e...

Page 14: ...carefully slide out tube connections are flexible STEP 4 Clean off accumulated dirt from condensing coil with a stiff bristle brush STEP 5 Lift cardboard cover above fan at plastic plugs and carefully...

Page 15: ...pose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter material in front...

Page 16: ...STAINLESS STEEL 1 USING THE CORRECT CLEANING TOOLS Use non abrasive tools when cleaning your stainless steel products The stainless steel s passive layer will not be harmed by soft cloths and plastic...

Page 17: ...ulb 2 GENERAL MAINTENANCE LIGHT BULB REPLACEMENT IDL INTEGRATED DOOR LIGHTING WARNING When replacing a light bulb make sure power to the unit is either turned off or unplugged IDL INTEGRATED DOOR LIGH...

Page 18: ...vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for labor or parts must be made directly throughTRUE All claims should include mo...

Reviews: