INSTALLATION / OPERATION INSTRUCTIONS
Leg levelers in the bottom of the cabinet
can be backed out for leveling.
Leg Levelers:
If the cabinet is not level use an open-end wrench and turn
adjustable tips on legs until cooler is level. (See image 1).
Castor Installation:
(Kit Contents)
2 - Castor mounting bracket
2 - Castor, 2-1/2” diameter wheel with 3/8” - 16 x 1-
1/2” threaded stem without brake
2 - Castor, 2-1/2” diameter wheel with 3/8” - 16 x 1-
1/2” threaded stem with brake
4 - Washer, flat, 3/8” I.D. x 1” O.D.
4 - Washer, split lock, 3/8” I.D.
4 - Nut, hex, 3/8” - 16
(See image 2).
CAUTION
To avoid damage to lower rail assembly, slowly raise unit to
upright position after installing castors.
2
A.
Before your new unit is connected to a power supply,
check the incoming voltage with a voltmeter. If
anything less than 100% of the rated voltage for
operation is noted, correct immediately.
B.
All units are equipped with a service cord, and must
be powered at proper operating voltage at all times.
Refer to cabinet data plate for this voltage.
TRUE
requires that a sole circuit be dedicated for the unit.
Failure to do so voids warranty.
WARNING
Compressor warranties are void if compressor burns out due
to low voltage.
WARNING
Power supply cord ground should not be removed!
WARNING
Do not use electrical appliances inside the food storage
compartments of the appliances unless they are of the
type recommended by the manufacturer.
NOTE
To reference wiring diagram - Remove lower rear grill. Wiring
diagram is positioned on the inside cabinet wall.
ELECTRICAL INSTRUCTIONS
LEVELING
Securing Castors
A.
Set unit in its final location. Be sure there is adequate
ventilation in your room. Under extreme heat
conditions, you may want to install an exhaust fan.
WARNING
Warranty is void if ventilation is insufficient.
B.
Proper leveling of your TRUE cooler is critical to
operating success (for non-mobile models). Effective
condensate removal and door operation will be
effected by leveling.
C.
The cooler should be leveled inside the cabinet front
to back and side to side with a level.
D.
Ensure that the drain hose or hoses are positioned in
the pan.
E.
Free plug and cord from inside the lower rear
of the cooler (do not plug in).
F.
The unit should be placed close enough to the
electrical supply so that extension cords are never
used.
WARNING
Cabinet warranties are void if OEM power cord is tampered
with. TRUE will not warranty any units that are connected to an
extension cord.
INSTALLATION OF LEGS AND CASTORS
1