Fault A111: Motor
Controller Fault
AC MCB
Illegal Speed
Command
Dirty or misaligned
speed sensor
Contact dealer or TRUE service
High Belt Deck Friction
Lubricate treadbelt
Contact dealer or TRUE service
Low Line Voltage
Check AC line voltage
Fault A112: Motor
Controller Fault
AC MCB
Phase over
current(RMS)
Loose Cable Connection
Power cycle
Check cable connections
Motor Control Board
Contact dealer or TRUE service
Fault A113: Speed
Sensor Fault
AC MCB
Faulty Speed
Sensor
Dirty or misaligned
speed sensor
Contact dealer or TRUE service
High Belt Deck Friction
Lubricat treadbelt
Contact dealer or TRUE service
Low Line Voltage
Check AC line voltage
Fault A114: Motor
Over Temp
AC MCB Heat Sink Over
Temperature
High Belt Deck Friction
Lubricat treadbelt
Contact dealer or TRUE service
Low Line Voltage
Check AC line voltage
Fault A115: Motor
Over Temp
AC MCB
Over
Temperature on
Motor Drive
High Belt Deck Friction
Lubricat treadbelt
Contact dealer or TRUE service
Low Line Voltage
Check AC line voltage
Fault A116: Motor
Controller Fault
AC MCB
Brake Gate
Driver Fault
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE service
MCB
Fault A117: Motor
Controller Fault
AC MCB
Phase A Low
Gate Driver Fault
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE service
MCB
Fault A118: Motor
Controller Fault
AC MCB
Phase B Low
Gate Driver Fault
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE service
MCB
Fault A119: Motor
Controller Fault
AC MCB
Phase C Low
Gate Driver Fault
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE service
MCB
Fault A120: Motor
Controller Fault
AC MCB
Output Peak
Over Current
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE service
MCB