S. 32
Each Template contains an assignment of the information in a customer-specific file (text file), to the
information important for the IQ.
Example profile
„IQ default“:
Line in the customer file, which is read:
01276;0523986512088;Max;Mustermann;2;30
The separator of the individual data is a semicolon. This is entered in the "Delim." field in the
template selection above. "length" denotes the number of data in one line, here 6.
Via PIN, RFID, Name, Given Name, max per day, Timeout and valid until the positions of the
respective value are indicated in the text line. A "0" means that this field is not read!
As an example, the PIN number "01276" is in the first position and is set with "1". "Maximum tapping
operations per day" is in the 5th position. The value "max per day" can be any value. The value "0"
cancels the restriction, so tapping can be done without restriction.
The value Timeout (blocking time after tapping) describes the time in minutes during which tapping
is not possible after the tapping process has been completed. A value of "0" also removes the lock.
"valid until" determines the time limit by means of date. The customer can thus only tap up to the
time of the set date. A set "0" deactivates this function.