Tap
General Settings
Mixer Still water, mixer CO2
Here the mixers can be adapted to the technical conditions of the respective plant
CO2 valve delay
Carbonic acid accumulates in front of the carbon dioxide valve, which causes a time delay between
switching on the valve and the water outlet.
If the output quantity is too small when tapping beverages with CO2, this can be corrected by
increasing this time (in ms).
CO2 admixture in %
For beverages containing CO2, set the proportion of CO2 water for normal operation (not effective in
Mode "Canteen operation"). The default value is 40% and should not be changed.
Concentrate Reduction
Activates the deduction of the tapped liquid from the total volume of water, so that the
quantity in the output is exactly maintained.
Intensity Setting
Lets the customer choose between three presets for the concentration of the liquid addition.
normal mode
Customer can choose from mixers (normal water, CO2 water or similar) and quantities.