22
Error
Rectification
LED flashes** 4 x
Defective wiring.
Temperature sensor or ca-
ble defective.
Address defect in wiring.
Replace temperature sensor.
LED flashes** 5 x
Temperature sensor or ca-
ble defective.
Replace temperature sensor.
* Reset the flash code:
takes place automatically after addressing the cause.
** Reset the flash code:
disconnect the mains voltage after addressing the cause
and disconnect battery (approx. 1 minute).
Flashing frequency:
0.2 s on, 0.2 s off, period between the flashing sequence 2 s.
If this does not solve the problem, please contact the
Truma Service.