Ensure that the ventilation slits remain free! There
should be a minimum clearance of 100 mm all round!
Inadequate ventilation can cause the device to overheat!
The device is designed for operation in an ambient tempera-
ture of up to 35 °C. If the temperature inside the device in-
creases due to a lack of circulating air or due to the fact that
the ambient temperature is too high, the charging current is
automatically reduced gradually.
Handling of the cage tension spring
clamps
Prepare the connection cables. The cable end to be connected
to terminal B+ (small caged spring terminal) must be stripped
over a length of 8 – 9 mm. The cable ends for the battery con-
nections (large cage tension spring clamps) must be stripped
11 – 12 mm. Cable end sleeves are not required.
The spring terminal can be opened up with the aid of a suit-
able slit screwdriver.
Insert the tip of the screwdriver into the upper, square open-
ing, and push on the spring terminal. The spring terminal in
the lower, round opening opens up.
Insert the cable into the spring terminal as far as the insula-
tion (lower, round opening) and remove the screwdriver. The
tension spring clamp closes again and the cable is securely
clamped.
Repeat the procedure for all connections:
B+ Battery sense, + Battery, - Battery.
Make sure that the cable ends sit firmly in the cage tension
spring clamps!
Connection
Disconnect the power cables from the battery and from
the mains before connecting or disconnecting any cables!
Only use the specified cross-sections and fuses with the cor-
rect rated current!
Positive charger cable red
Cable cross section 6 mm²
Negative charger cable blue
Cable cross section 6 mm²
B+ measuring line red
Cable cross section 0,75 mm²
Battery connection
Connect the charger to the battery as shown in the diagram
(fig. 6). Pay attention to the cable cross-sections and ensure
correct polarity.
Connect the negative charger cable (blue 6 mm²) to the
negative terminal of the charger and the negative terminal
of the battery.
Connect the positive charger cable (red 6 mm²) to the positive
terminal of the charger for the battery and the positive terminal
of the battery. Secure this line with a 30 A fuse (not included in
the delivery) close to the positive terminal of the battery!
Connect the measuring cable (red 0.75 mm²) to the B+ in-
put of the device and the positive pole of the battery. Secure
this line with a 2 A fuse (not included in the delivery) close
to the positive terminal of the battery!
We recommend connecting the negative pole of the battery to
the vehicle‘s chassis – minimum cross-section 10 mm².
If the Mover® PowerSet / PowerSet Plus is interconnected with
the autarkic electrical installation of the vehicle, the negative
–
–
–