FITTED EQUIPMENT
140
DOMETIC REFRIGERATOR
Refrigerator operation
The refrigerator is equipped to operate on
three power modes:
• Mains voltage (230V AC)
• Direct-current voltage (12V DC)
•Gas (liquid gas propane/butane)
Select the desired power mode by the energy
selector switch (battery igniter type models)
or the MODE button (MES, AES). Appliances
with automatic energy selection (AES) are
additionally provided with “automatic mode”
function. The AES system automatically
selects the best energy source for each
particular situation.
Cleaning
Before starting up the refrigerator, it is
recommended that you clean it inside and
repeat this at regular intervals.
Use a soft cloth and lukewarm water with a
mild detergent. Then wipe out the appliance
with clean water and dry thoroughly.
To avoid material alterations, do not use soap
or hard, abrasive or soda-based cleaning
agents.
Do not allow the door seal to come into
contact with oil or grease.
Maintenance
• In compliance with the applicable
regulations, please note that the gas unit
and the connected ventilation ducts must be
checked by authorised technical personnel
after first use and after every other year for
compliance with the European Standard EN
1949. A test certificate has to be issued. It is
the user’s responsibility to arrange this test.
• The gas burner must be inspected and
cleaned as necessary at least once a year.
When using liquefied petroleum gas (tank
or refill cylinders) the maintenance interval is
reduced to half-yearly or quarterly. Keep the
evidence of maintenance work carried out on
your refrigerator.
• Work on gas and electrical equipment shall
be carried out by qualified personnel only.
It is recommended that this is carried out by an
authorised customer services department.
We recommend maintenance following an
extended shutdown of the vehicle. Please
contact our customer services.
Manual energy selection
/ automatic ignition (RM 8xx1)
MES (fridge models)
Fig. 7
1
2
3
4
6
7
8
9
1 -
Power ON/OFF switch
2 -
Energy selector button 230V ~
3 -
Energy selector button GAS
4 -
Energy selector button 12V =
6 -
Temperature level selection
7 -
Temperature level display
8 -
Indicator LED failure / Reset button
GAS FAILURE
Switching ON/OFF
• Switch ON by pressing button (1), 2s
• Switch OFF by pressing button (1), > 2s
230V AC operation
• Select “Mains voltage” by pressing button (2)
• Set temperature step by pressing button (6)