background image

 

  7 

Disposal 

The device must be disposed of in line with the administrative 

regulations of the respective country in which it is used. National 
regulations and laws must be observed. 

Technical data 

determined in accordance with EN 624 or Truma test conditions 

Type of gas 

 

LPG (Liquefied Petroleum Gas 

 propane / butane) 

Operating pressure

 

2.75 kPa (see type plate) 

Water contents

 

10 litres 

Heating up time from approx. 15 °C to approx. 60 °C 

Boiler approx. 

23 minutes (measured according to EN 15033)  boiler approx. 
90 min. 

Pump  pressure 

max.  0.28 

MPa 

System  pressure 

max. 

0.45  MPa 

Nominal  input 

(Propane) 

Combi 2 E CP plus (Australia):  

6.9 MJ/h 

Combi 4 E CP plus (Australia):  

Thermal output

 

13.6 MJ/h 

Electrical operation (240 V):

 

 

980 W / 1960 W 

Mixed operation (gas and electrical): max. 3900 W 
Gas operation  
Combi 2 E CP plus (Australia):  

max. 1950 W  

Combi 4 E CP plus (Australia):  

Gas consumption 

(Propane) 

max. 3900 W 

Combi 2 E CP plus (Australia):   

130 g/h 

Combi 4 E CP plus (Australia):  130 

 260 g/h 

Air delivery 

volume

 (free-blowing without hot-air pipe) with 

3

 hot-air 

outlets max. 249 m³/h with 

4

 hot-air outlets max. 287 m³/h 

Current input at 12 V

 

 boiler 
Short-term max. 5.6 A (average power consumption 1.1 A) 
Heating up of boiler: 0.4 A 
Stand-by: 0.001 A 

Current input at 240 V

 

4.1 A (980 W) or 8.1 A (1960 W)  

Weight 

(not containing water) 

Heater unit:  

  

15.8 kg 

Heater unit with peripheral devices:  16.4 kg 

Declaration of conformity

 

The heater Combi 2 E / 4 E CP plus (Australia) is approved according 

AS 4552, AS 4556, AS/NZS 60335.2.21+A1-A3, AS/NZS 
60335.2.30+A1, AS/NZS 60335.1+A1 and fulfills these standards: 

 

Dimensions 

 

Fig. 7 

The right to effect technical modifications is reserved! 

Truma warranty policy 

 

Truma CP plus 

The warranty is given by Dometic Pty Ltd, Building 3B,  

Digital control panel Truma CP plus (part no. 36020-01). 

Clayton Business Park, 1508 Centre Road, Clayton, Victoria, 3168, 
for 12 months from the date of purchase against any defect arising 
from faulty materials or workmanship. 

Repairs will be carried out during normal business hours only by Dometic Pty Ltd, or its duly 
authorised service agents, and are subject to the warranty conditions and exclusions 
hereunder. 

Warranty conditions

 

 

The company will only provide service on presentation  of proof 
of purchase, on either the Truma product, or the Caravan / RV / 
Pleasure Craft in which the Truma product  

Fig. 8 

has been 

installed, to any authorised service agent. The pur- 

chaser must allow the service agent to photocopy the proof of 

purchase to facilitate his claim to the manufacturer.  

Accessories (without picture) for control panels 

 Warranty repairs can only be performed by authorised ser- 

 Cable 3 m (part no. 36110-

01)  

vice agents and under no circumstances will Dometic reim- 

 

Cable 6 m (part no. 36110-02)   burse repairs carried out by 
unauthorised persons. Tamper- 

 

Cable 9 m (part no. 36110-03)   ing with any part of the product 
by unauthorised personnel  
will automatically void the warranty.  

 

The product must be used solely for domestic purposes  only. If 
the product is used for commercial purposes the warranty is 6 
months only.  

 

Where applicable, the products must be used on the ap- propriate 
electrical voltage, gas type and pressure, or fuel source.  

 

If at any time during the warranty period any part or parts  are 
replaced with a part or parts not supplied or approved by  Truma, 
this warranty shall immediately become void.  

5375

 

Summary of Contents for Combi 2E CP plus

Page 1: ...Combi 2 E 4 E CP plus Australia Operating instructions Page 2 Installation instructions Page 9 To be kept in the vehicle...

Page 2: ...ion 5 Gas connection with pressure test point not shown 6 Hot air outlets 7 Recirculated air intake 8 Waste gas discharge 9 Combustion air infeed 10 Electronic control unit 11 Water container 10 litre...

Page 3: ...unit gas mode only LPG for autonomous use electrical mode only 240 V for stationary use on camp sites or gas and electrical mode mixed mode Only possible in heating and hot water mode Heating and hot...

Page 4: ...essure control systems DuoControl CS for dual cylinder gas systems At temperatures of around 0 C or less the gas pressure regulator and the changeover valve should be operated using the EisEx regulato...

Page 5: ...er that has frozen The boiler can be thawed out again by briefly starting it up max 2 minutes Frozen lines can be thawed out by heating up the interior If connected to a central water supply rural or...

Page 6: ...switch If the 12 V power supply is interrupted during operation or during the after run period for example the temperatures within the unit could activate the overheating protection Fig 6 To reset th...

Page 7: ...Dimensions Fig 7 The right to effect technical modifications is reserved Truma warranty policy Truma CP plus The warranty is given by Dometic Pty Ltd Building 3B Digital control panel Truma CP plus pa...

Page 8: ...s Apart from any warranties implied by the Trade Practices Act 1974 or any relevant State legislation all other warranties express or implied whether arising by virtue of statute or otherwise are here...

Page 9: ...on with the original Fig 9 In order to heat the vehicle evenly throughout the heater must be installed in a location in the vehicle that is as central as possible in a wardrobe stowage compartment or...

Page 10: ...e heating device assembly instructions are enclosed with the delivery Installing the wall cowl Permissible duct lengths The length specific ations refer to the combusti on air intake duct Ducts with a...

Page 11: ...et of the unit in confined spaces we recommend the use of the BGC 90 elbow part no 34091 01 This elbow makes it possible to connect a R warm air duct with a diameter of 65 mm or a VR warm air duct wit...

Page 12: ...s 27 28 and safety drain valve 24 have a 12 mm rigid piping connection e g John Guest System For connecting to rigid pipes with other diameters appropiate adapters not included in scope of delivery mu...

Page 13: ...e regulation we recommend that the room temperature sensor be fitted above the entrance door Fig 26 Please ensure that the room temperature sensor is always attached to a vertical wall There may be no...

Page 14: ...from Truma for the different applications Please ask your dealer Other chargers may be used only with a 12 V battery as a buffer Room temperature sensor Attach plug of connecting cable to connection 4...

Page 15: ...Dometic Service C entre if problems are encountered in other countries the relevant service partners should be contacted www truma com Having the e quipment model and the serial number ready see type...

Page 16: ...Road Clayton Victoria 3168 Australia Service Australia Telephone 61 0 3 92 39 10 50 Facsimile 61 0 3 92 39 10 99 Dometic New Zealand Ltd Post Box 12011 1642 Penrose Auckland New Zealand Service New Z...