17
Mixed mode
(Combi Diesel E only)
Fault in the 230 V power supply
The yellow LED (o) on the power selector switch goes off and
the yellow LED (g) on the control panel flashes 2 x.
Refer to the troubleshooting guide for possible causes.
If the 230 V power supply is interrupted during mixed mode,
the heater will automatically switch to diesel mode. As soon
as the 230 V power supply has been restored, the heater
automatically switches back to mixed mode.
Fault in the combustion procedure
The yellow LED (o) on the power selector switch illuminates
and the red LED (h) or the yellow LED (g) on the control panel
flashes.
Refer to the troubleshooting guide for possible causes.
If the flame goes out during mixed mode (e.g. empty gas cylinder
or closed exhaust outlet), the heater automatically switches
to electric mode. For the heater to operate in mixed mode
again, the cause of the fault must be remedied and the heater
switched off and on again at the control panel (fault reset).
Accessories
Cover frames are available as accessories.
For the visual finish, side parts are available to match the
cover frame. Please contact your specialist dealer in this
connection.
Line-up clip, 1 pc. (part no. 34000-65900) for connecting two
cover frames.
Other accessories (without picture) for control panel:
– Control panel cable in various lengths (maximum 10 m)