9
Improper use
The device may not be used as a charger.
It is not suitable for operating consumers that require a fil-
tered, stabilised voltage such as audio equipment, electrical
controllers and Truma boilers.
Description
The device has an automatic switchover facility to switch
between mains supply and battery mode, mains supply takes
priority. In mains supply mode, the connected consumers are
supplied with 12 V unfiltered power via a transformer and a
downstream rectifier. If the mains power supply is interrupted,
the unit automatically changes over to the connected battery.
1
3
4
2
+
+
1 230 V circuit breaker with a manual button
2 230 V mains input – device plug
3 12 V input – from the battery
4 12 V output – to the consumers
Commissioning
The device is operational as soon as there is power supplied to
one of the two inputs and the device‘s 230 V circuit breaker is
switched on in mains supply mode.
Switching off
To switch off, press the manual button on the 230 V circuit
breaker (1).
Maintenance
The power supply must always be disconnected before
performing any maintenance work on the device.
Clean the device and the ventilation slits with a dry and fluff-
free cloth.
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.