background image

 

   

                                                                                                                                                     

5

 

 

 

 

 

 

 

5.4.2 System mount 

1.  Solar modules produce electrical energy 

when light shines on their front surface. 

The DC voltage may exceed 30V. If 

modules are connected in series, the total 

voltage is equal to the sum of the individual 

module voltage. If modules are connected 

in parallel, The total current is equal to the 

sum of the individual module current.

 

Do 

not disconnect during load connection for a 

removable connector. 

2.  Keep children away from the system while 

transporting and installing mechanical and 

electrical components. 

3.  Completely cover the module with an 

opaque material during installation to keep 

electricity from being generated. 

4. 

Do not wear metallic rings, 

watchbands,ear,nose,lip rings or other 

metallic devices while installing or 

troubleshooting photovoltaic systems. 

 

 

 

 

 

Only use approved insulate tools for 

electrical installation work. 

 

 

 

 

5.  Abide with safety regulations for all other 

components used in system, including 

wiring and cables,connectors,charging 

regulators,inverters,storage batteries and 

rechargeable batteries,etc. 

6.  Use only equipment,connectors,wiring and 

support frames suitable for use in a solar 

electric system. Always use the same type 

of module within a particular photovoltaic 

system. 

6 ELECTRICAL INSTALLAIONS 

6.1 Bypass diodes 

Modules contain bypass diodes when shipped   

from the factory. 

If the service personnel need to replace the 

damaged bypass diodes, at least one diode 

should be installed in    each string. 

Only qualified personnel are permitted to install 

the bypass diodes.   

Open the cover of junction box and install 

diodes in each two conductors. Only diode with 

the same model type is permitted to be used. 

6.2  Over current protection 

Whenever necessary to comply with local 

codes, use a fuse or circuit breaker, rated for 

the maximum series fuse rating of the module 

and the system voltage. 

Always fuse the connections at the battery for 

safety. Refer to the module rating label (on 

module) for recommended fuse size. Also, refer 

to the charge controller owner’s manual. 

When the modules are connected in parallel, 

each module or each string of module shall be 

provided with a fuse with the maximum series 

fuse rating as indicated in “Electrical 

Specification”. 

All electrical components should have ratings 

equal or greater to the system rating. Do not 

exceed the maximum allowable system voltage 

as listed on the module label. 

 

 

Summary of Contents for TSM175-72

Page 1: ...ificially concentrate sunlight onto the modules 2 INTRODUCTIONS TRUNSUN SOLAR modules come in various sizes to satisfy a full range of applications Each module is made of crystalline silicon cells To...

Page 2: ...essures greater than 112 9pounds per square foot 551Kg m2 of uniformly distributed wind snow or other loading The modules have been tested by TUV for a maximum front loading of 5400Pa backside loading...

Page 3: ...cture using 8 holes for normal installation as indicated in figure 1 Load calculations shall be done by the system designer or installer Each hole shall be installed in the order as in the following f...

Page 4: ...ion required to mount the module must be properly sealed to prevent leaks 5 In some cases a special support frame may be necessary 6 The roof installation of solar modules may affect the fireproofing...

Page 5: ...g and support frames suitable for use in a solar electric system Always use the same type of module within a particular photovoltaic system 6 ELECTRICAL INSTALLAIONS 6 1 Bypass diodes Modules contain...

Page 6: ...ame of module All module frames should be grounded for safety The grounding connections between modules must be approved by a qualified electrician the grounding itself must be made by a qualified ele...

Page 7: ...er additional wires with pre attached connectors may be used The wire shall be PV wire or USE 2 wire the connectors shall be manufactured by Multi Contact USA with model type PV KBT4 6II UR female and...

Page 8: ...to as little as 5 of full sunlight and both current and power increase with light intensity Do not touch live parts of cables and connectors As an additional precaution use insulated tools and rubber...

Page 9: ...talled by the manufacturer Do not treat the back of the module with paint or adhesives If not otherwise specified it is recommended that requirements of the latest local national or regional electrica...

Page 10: ...crystalline silicon PV module TSMxxx 72 NOTE TSM 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 11: ...crystalline silicon PV module TSPxxx 54 NOTE TSP 54 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 12: ...crystalline silicon PV module TSMxxx 60 NOTE TSM 60 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 13: ...crystalline silicon PV module TSMxxx 60 NOTE TSM 60 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 14: ...crystalline silicon PV module TSPxxx 60 NOTE TSP 60 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 15: ...crystalline silicon PV module TSPxxx 60 NOTE TSP 60 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 16: ...crystalline silicon PV module TSMxxx 72 NOTE TSM 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 17: ...crystalline silicon PV module TSMxxx 72 NOTE TSM 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 18: ...crystalline silicon PV module TSPxxx 72 NOTE TSP 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 19: ...crystalline silicon PV module TSPxxx 72 NOTE TSP 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 20: ...4 6 9 17 5 1480 991 50 35 195 1000 30 80 8 50 25 70 7 59 13 3 A C 15 32 1 TSP200 54 Poly 54 6 9 17 5 1480 991 50 35 200 1000 31 30 8 58 26 10 7 66 13 6 A C 15 31 1 TSP205 54 Poly 54 6 9 17 5 1480 991...

Page 21: ...5 25 1 TSM275 60 Mono 60 6 10 18 5 1650 991 40 28 275 1000 39 36 9 09 32 55 8 45 16 8 A C 15 25 1 TSM280 60 Mono 60 6 10 18 5 1650 991 40 28 280 1000 39 48 9 21 32 72 8 56 17 1 A C 15 25 1 TSM285 60 M...

Page 22: ...5 21 1 TSM300 72 Mono 72 6 12 22 5 1956 991 45 35 300 1000 46 55 8 53 37 65 7 97 15 5 A C 15 21 1 TSM305 72 Mono 72 6 12 22 5 1956 991 45 35 305 1000 46 68 8 62 37 89 8 05 15 7 A C 15 21 1 TSM310 72 M...

Page 23: ...21 1 TSP315 72 Poly 72 6 12 22 5 1956 991 45 35 315 1000 46 58 8 81 37 91 8 31 16 3 A C 15 21 1 TSP320 72 Poly 72 6 12 22 5 1956 991 45 35 320 1000 46 72 8 89 38 19 8 38 16 5 A C 15 21 1 TSP325 72 Po...