Customers 

The fault probability of the modules in the later 

operation is extremely low. 

 

You can use the below fault judgment methods:

 apperance defects, such as break, cracked, su

rface stripping and so on, the electrical perform

ance of the whole string or of the whole module

 failed. 

 

For the fault modules, you cannot disassemble 

them by yourself. Disassembling must be exec

uted by qualified experts. You should contact o

ur sales persons at once to apply for repaire or 

replacement of the fault modules. (the modules

 need to be replaced must be the same kind  a

nd type ,if needed) . 

 

Modules can operate effectively without ever   

being washed, although removal of dirt from the 

front glass can increase output. The glass can 

be washed with a wet sponge or cloth. Wear 

rubber gloves for electrical insulation. 

8 SAFETY PRECAUTIONS 

Module installation and operation should be 

performed by qualified personnel only. Children 

should not be allowed near the solar electric 

installation. Modules of unpacking, transport, 

installation process must be handled with care. 

To avoid collision with the sharp and hard 

objects so as not to cause damage and affect 

the normal use. 

Module must be installed in the absence of 

shadowed areas, otherwise it will not work to 

generate electricity. If the module long 

shadowing state (dust and bird feces shadowed) 

to work, it will Breakdown caused by 

overheating 

Avoid electrical hazards when installing, wiring, 

operating and maintaining the module. Modules 

produce DC electricity when exposed to light 

and therefore can produce an electrical shock 

or burn. Modules produce voltage even when 

not connected to an electrical circuit or load. 

Modules produce nearly full voltage when 

exposed to as little as 5% of full sunlight and 

both current and power increase with light 

intensity. Do not touch live parts of cables and 

connectors. As an additional precaution, use 

insulated tools and rubber gloves when working 

with modules in sunlight. 

Fall of modules from high place will cause 

death, injury or damage. Do not drop module or 

allow objects to fall on module. Never leave a 

module unsupported or unsecured. If a module 

should fall, the glass can break. A module with 

broken glass cannot be repaired and must not 

be used. 

When installing or working with module or 

wiring, cover module face completely with 

opaque material to halt production of electricity. 

Modules have no on/off switch. Modules when 

exposed to sunlight generate high voltage and 

are dangerous. Modules can be rendered 

inoperative only by removing them from 

sunlight, or by fully covering the front surface 

with opaque cloth, cardboard, or other 

completely opaque material, or by working with 

modules face down on a smooth, flat surface 

when installing or maintaining. 

Do not expose the artificially concentrated 

sunlight to a module.   

Trunsun modules are designed to fulfill the 
criteria of Application class A requirements 
according to IEC61730-1.Modules rated for use 
in application class A may be used in systems 
operating at greater than 50V DC or 240W, 
where general contact access is anticipated. 
Modules qualified for safety through 
IEC61730-1 and IEC61730-2 within application 
class A are considered to meet the 
requirements for safety class 

 referring to 

IEC61140. 

 

Modules can produce higher output than the 

rated specifications. Industry standard ratings 

are made at conditions of 1000 W/m2 and 25°C 

cell temperature. Reflection from snow or water 

can increase sunlight and therefore boost 

current and power. In addition, colder 

temperatures can substantially increase voltage 

and power. Modules are intended for use in   

 

terrestrial  

Summary of Contents for TSM175-72

Page 1: ...ificially concentrate sunlight onto the modules 2 INTRODUCTIONS TRUNSUN SOLAR modules come in various sizes to satisfy a full range of applications Each module is made of crystalline silicon cells To...

Page 2: ...essures greater than 112 9pounds per square foot 551Kg m2 of uniformly distributed wind snow or other loading The modules have been tested by TUV for a maximum front loading of 5400Pa backside loading...

Page 3: ...cture using 8 holes for normal installation as indicated in figure 1 Load calculations shall be done by the system designer or installer Each hole shall be installed in the order as in the following f...

Page 4: ...ion required to mount the module must be properly sealed to prevent leaks 5 In some cases a special support frame may be necessary 6 The roof installation of solar modules may affect the fireproofing...

Page 5: ...g and support frames suitable for use in a solar electric system Always use the same type of module within a particular photovoltaic system 6 ELECTRICAL INSTALLAIONS 6 1 Bypass diodes Modules contain...

Page 6: ...ame of module All module frames should be grounded for safety The grounding connections between modules must be approved by a qualified electrician the grounding itself must be made by a qualified ele...

Page 7: ...er additional wires with pre attached connectors may be used The wire shall be PV wire or USE 2 wire the connectors shall be manufactured by Multi Contact USA with model type PV KBT4 6II UR female and...

Page 8: ...to as little as 5 of full sunlight and both current and power increase with light intensity Do not touch live parts of cables and connectors As an additional precaution use insulated tools and rubber...

Page 9: ...talled by the manufacturer Do not treat the back of the module with paint or adhesives If not otherwise specified it is recommended that requirements of the latest local national or regional electrica...

Page 10: ...crystalline silicon PV module TSMxxx 72 NOTE TSM 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 11: ...crystalline silicon PV module TSPxxx 54 NOTE TSP 54 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 12: ...crystalline silicon PV module TSMxxx 60 NOTE TSM 60 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 13: ...crystalline silicon PV module TSMxxx 60 NOTE TSM 60 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 14: ...crystalline silicon PV module TSPxxx 60 NOTE TSP 60 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 15: ...crystalline silicon PV module TSPxxx 60 NOTE TSP 60 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 16: ...crystalline silicon PV module TSMxxx 72 NOTE TSM 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 17: ...crystalline silicon PV module TSMxxx 72 NOTE TSM 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 18: ...crystalline silicon PV module TSPxxx 72 NOTE TSP 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 19: ...crystalline silicon PV module TSPxxx 72 NOTE TSP 72 Electrical Specification and Mechanical Specification can be found in the last page Electrical Specification and Mechanical Specification D C down...

Page 20: ...4 6 9 17 5 1480 991 50 35 195 1000 30 80 8 50 25 70 7 59 13 3 A C 15 32 1 TSP200 54 Poly 54 6 9 17 5 1480 991 50 35 200 1000 31 30 8 58 26 10 7 66 13 6 A C 15 31 1 TSP205 54 Poly 54 6 9 17 5 1480 991...

Page 21: ...5 25 1 TSM275 60 Mono 60 6 10 18 5 1650 991 40 28 275 1000 39 36 9 09 32 55 8 45 16 8 A C 15 25 1 TSM280 60 Mono 60 6 10 18 5 1650 991 40 28 280 1000 39 48 9 21 32 72 8 56 17 1 A C 15 25 1 TSM285 60 M...

Page 22: ...5 21 1 TSM300 72 Mono 72 6 12 22 5 1956 991 45 35 300 1000 46 55 8 53 37 65 7 97 15 5 A C 15 21 1 TSM305 72 Mono 72 6 12 22 5 1956 991 45 35 305 1000 46 68 8 62 37 89 8 05 15 7 A C 15 21 1 TSM310 72 M...

Page 23: ...21 1 TSP315 72 Poly 72 6 12 22 5 1956 991 45 35 315 1000 46 58 8 81 37 91 8 31 16 3 A C 15 21 1 TSP320 72 Poly 72 6 12 22 5 1956 991 45 35 320 1000 46 72 8 89 38 19 8 38 16 5 A C 15 21 1 TSP325 72 Po...

Reviews: