background image

Turning On

• Turn ON the air compressor and let it fill up.

• Regulate the air compressor outlet pressure to 90 PSI.

 

                   The tool operates with this pressure 

range.  If operating in a higher pressure range the tool 

useful life will be shorter.

• Let run some air through the hose and coupling to 

verify both are clean before connecting into the tool.

• Select the adequate rotation direction and torque.

• Press the trigger so that the die can rotate.

• Release the trigger to stop the die.

Rotation Direction and Torque Selection

• Rotation direction is adjusted with the torque selector (

F

).

• To tighten a nut or lug, turn the selector to the right so 

that the die rotate on clockwise. To loosen turn the knob to 

the left to make the die rotate counter clockwise.

• To select torque and prevent from tightening too much, a 

nut or lug, turn the knob to the right or to the left until 

reaching the desired torque level.

•  Using the maximum torque is recommended when there 

is no torque meter to verify the adequate torque.

• The torque value may vary depending on the air 

compressor size and the quantity of air (CFM) it delivers. 

Operation

• Set the die in the nut or lug you want to loosen or 

tighten.

• Before operating the tool double check there is enough 

space in the back of the tool to prevent getting your hand 

trapped. The tool goes away from the nut / screw when 

loosened or tightened.

• Do not try to make contact with the nut or lug with the 

die moving. Do not press the trigger unless the nut or lug 

is set correctly inside the die.

• Apply firm and constant pressure without forcing the 

tool. Otherwise it can be damaged.

Air Outlet Connection

• Remove the plastic capo (

A

) covering the air inlet in the 

handle base.

• Before each use add three to six drops of lubricant with 

no detergent (

B

) into the air inlet (

C

).

• Screw the quick connector (

D

) (not included) to the air 

inlet.

• Connect the air hose using a fast nipple (

E

), (not 

included) into the quick connector.

WARNING

8

Start Up

Trigger

B

A

E

C

F

D

ENGLISH

Summary of Contents for 16889

Page 1: ...X 2 Model Code TPN 776X 2 Applies for 16889 3 4 Manual Use oil continuously and dosed to lubricate the tool Air impact wrench WARNING CAUTION Read this manual thoroughly before using the tool ENGLISH...

Page 2: ...ers Warranty Policy 3 3 4 5 7 7 8 9 9 10 11 12 TPN 776X 2 ENGLISH Contents CAUTION Keep this manual for future references The illustrations in this manual are for reference only They might be differen...

Page 3: ...n in the hoses before using the tool See the compressor instructions Please consider the increase in pressure in the line or the hose inner diameter to compensate the use of too long hoses more than 3...

Page 4: ...zard of severe personal injuries or crushing Wear adequate protective safety accessories Wear eye protection dust mask non skid safety shoes helmet and ear plugs In normal conditions the risk of injur...

Page 5: ...particles Pneumatic tools do not have electric insulation If during the operation the tool makes contact with a source of electricity the energy will be conducted to the operator causing a fatal elect...

Page 6: ...from sharp or abrasive edges Unplug the hose when setting up accessories like grinding discs or bits Never use the hose to carry the tool Never pull the hose to unplug it Do not expose the hose to hea...

Page 7: ...hand tools Consult the catalog to learn about our accessory s variety Use 3 4 dies for box impellers Using adaptors for other sizes are not recommended Use only if strictly necessary If the die has or...

Page 8: ...que level Using the maximum torque is recommended when there is no torque meter to verify the adequate torque The torque value may vary depending on the air compressor size and the quantity of air CFM...

Page 9: ...covered with the Warranty We reserve the right to carry out technical improvements without notice Lubrication Service The tool runs too slow or is not working The tool rotor turns without auctioning...

Page 10: ...Notes 10 ENGLISH...

Page 11: ...SERVICIO ECLIPSE CALLE PRINCIPAL MZ 1 LT 1 COL SANTA FE C P 39010 CHILPANCINGO GRO TEL 747 478 5793 FERREPRECIOS S A DE C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 436...

Page 12: ...22 Col Centro Alc Cuauht moc CDMX C P 06060 or at the establishment where you purchased it or at any Truper Service Center listed in the annex to the warranty policy and or in www truper com Transpor...

Page 13: ...ducto en Corregidora 22 Col Centro Alc Cuauht moc CDMX C P 06060 o en el establecimiento donde lo compr o en alg n Centro de Servicio Truper de los enlistados en el anexo de la p liza de garant a y o...

Page 14: ...8 79 80 88 CENTRO DE SERVICIO ECLIPSE CALLE PRINCIPAL MZ 1 LT 1 COL SANTA FE C P 39010 CHILPANCINGO GRO TEL 747 478 5793 FERREPRECIOS S A DE C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLED...

Page 15: ...Notas 10 ESPA OL...

Page 16: ...rvicio ADVERTENCIA La herramienta funciona muy despacio o no funciona El rotor de la herramienta gira sin que se accione el gatillo Arenilla o goma en la herramienta La herramienta no tiene aceite Baj...

Page 17: ...de torque deseado Se recomienda utilizar el torque m ximo en caso de no contar con un torqu metro para verificar el torque adecuado El valor de torque puede variar dependiendo del tama o del compresor...

Page 18: ...el Cat logo para conocer nuestra gama de accesorios Utilice dados para impulsores de cuadro de 19 mm 3 4 Los adaptadores para dados de otras medidas no se recomiendan util celos s lo si es estrictame...

Page 19: ...ejada se superficies afiladas o abrasivas Desconecte la manguera cuando instale accesorios como discos de esmeril o brocas Nunca use la manguera para cargar la herramienta Nunca jale de la manguera pa...

Page 20: ...ci n llegan a hacer contacto con alguna fuente de electricidad conducir la energ a al operador provocando electrocuci n incluso fatal Riesgo de choque el ctrico Jam s utilice herramientas neum ticas p...

Page 21: ...e protecci n personal Utilice protecci n para los ojos Mascarilla antipolvo zapatos de seguridad antideslizantes casco y protecci n para los o dos en condiciones adecuadas reducen considerablemente el...

Page 22: ...de aire Consumo de aire 1 2 13 mm 3 8 NPT 9 5 mm Conexi n de entrada de aire Di metro interno de la manguera Frontal e inferior Especificaciones t cnicas Requerimientos de filtrado y lubricaci n Sist...

Page 23: ...icio Autorizados P liza de Garant a Guarde este Instructivo para futuras referencias Los gr ficos de este Instructivo son para referencia pueden variar del aspecto real de la herramienta 3 3 4 5 7 7 8...

Page 24: ...o C digo TPN 776X 2 Este Instructivo es para 16889 19 mm 3 4 ADVERTENCIA ATENCI N Lea este Instructivo por completo antes de usar la herramienta Utilice aceite de forma continua y dosificada para lubr...