OPERATION 

Air Filter: 

Screw the air filter (included) onto the port in the 

compressor side.  Do not operate the compressor if the air 

filter has not been previously set in place.

Switch: 

The switch shall be in the OFF position when plugging 

or unplugging the cable from the power outlet.

Regulator: 

The regulator controls the amount of air pressure 

released from the hose outlet. 

Safety Valve: 

When the outlet valve is completely closed the 

safety valve is activated to release air pressure. 

ALERT:

 If the unit has wheels included never use the handle to 

carry or lift it from the ground.  

LUBRICATION

This product does not use oil, thus it does not need lubrication 

to operate. 

BREATHING PROCEDURE

                     Do not connect chucks or any other tool to open 

the hose end until the unit has completely started and the 

inspection is positive.

                     Do not operate the compressor before reading 

the instructions; otherwise it could be dangerous using it. 

1. Turn completely the regulator to the right to open the 

airflow.

2. Turn off the switch and connect the cable. 

HUMIDITY IN THE COMPRESSED AIR

Humidity produced by compressed air can be observed, drops 

are present when air is coming out from the compressed air 

pump.

Humidity will increase when humidity is high or the 

compressor is under continuous use. Using a paint gun or any 

other substance makes water be transported through the hose.  

Then it will come out through the gun as drops combined with 

the material to be spayed.

                      This condensation will cause spaces with water.  

If working with sand, the material could get hard and clog the 

gun and it will stop working.  A filter in the air-line, set as close 

as possible to the gun could eliminate the humidity.

SAFETY VALVE

                      Do not remove or try to adjust the safety valve.

This valve shall be inspected regularly and under pressure.  

Pull the ring with your hand.  If air comes out after releasing 

the ring, or, when the valve is stuck and it cannot be moved 

with the ring IT SHOULD be replaced.

PRESSURE REGULATING KNOB

1. This knob controls the air pressure.

2. Turn the knob to the right to increase air pressure. When the 

desired pressure is reached, press the knob down to adjust 

again.

3. To diminish air pressure turn the knob to the left.

 

4

WARNING

WARNING

WARNING

WARNING

Switch

PRESSURE REGULATING KNOB

Summary of Contents for 19361

Page 1: ...MP POR 2 5 C digo 19361 NOTA IMPORTANTE Este producto no debe quedar expuesto a goteo o salpicaduras por l quidos Compresor port til de aire Instructivo Lea este Instructivo por completo antes de usar...

Page 2: ...bre la m quina o se cruce cuando est en funcionamiento 12 No extienda su radio de acci n Evite toda postura que cause cansancio Cuide de que su posici n sea segura y de que conserve el equilibrio 13 M...

Page 3: ...lta presi n las siguientes precauciones deber n tomarse en cuenta siempre 1 Siga todos los c digos de seguridad y electricidad local 2 El compresor deber usarse s lo por personas que est n dispuestas...

Page 4: ...zar todos los c digos el ctricos para estas cantidades 2 Utilice un interruptor o fusible de acci n lenta Si no se hace una conexi n adecuada se podr a provocar un sobrecalentamiento choque el ctrico...

Page 5: ...umedad producida por el aire comprimido se podr observar por medio de gotas mientras ste sale de la bomba de aire comprimido Cuando la humedad sea alta o cuando el compresor se encuentre en uso contin...

Page 6: ...esi n da ado 1 Est conectado Revise el fusible interruptor o sobrecarga de motor 2 Reemplace fusible da ado 3 Vuelva a iniciarlo determinar causa del problema 4 El motor volver a prender cuando se enf...

Page 7: ...o 670655 FERREPRECIOS S A DE C V LIBERTAD ORIENTE No 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO TEL 01 775 753 6615 16 Jalisco Guadalajara 670855 MAGNOCENTRO FERRETERO S A DE C V AV LA PAZ 118...

Page 8: ...e tener alg n problema para contactar un centro de servicio consulte nuestra p gina www truper com donde obtendr un listado actualizado o llame al Tel 01 800 690 6990 o 01 800 018 7873 donde le inform...

Page 9: ...Model COMP POR 2 5 Code 19361 Portable air compressor Manual IMPORTANT NOTICE This product should not be exposed to liquids dripping or splashing Read the user s manual thoroughly before operating th...

Page 10: ...ing one hand and enables to use both hands Keep proper footing and balance at all times Do not overreach over or walk across the tool when is running 12 Do not extend your range of action Avoid a stan...

Page 11: ...CIFIC SAFETY INSTRUCTIONS Since the air compressor and other components could produce high pressure pumping please use care and follow these caution measures 1 Follow all local safety and electricity...

Page 12: ...shock because it offers an escape cable to the electric current This product is built with and adequate grounded plug The plug shall be connected to a correctly installed and grounded power outlet th...

Page 13: ...UMIDITY IN THE COMPRESSED AIR Humidity produced by compressed air can be observed drops are present when air is coming out from the compressed air pump Humidity will increase when humidity is high or...

Page 14: ...switch or motor overload 2 Replace blown fuse 3 Restart and determine what caused the problem 4 The motor will be on when it cools down 5 Replace in a Truper Authorized Service Center The motor buzze...

Page 15: ...REPRECIOS S A DE C V LIBERTAD ORIENTE No 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO TEL 01 775 753 6615 16 Jalisco Guadalajara 670855 MAGNOCENTRO FERRETERO S A DE C V AV LA PAZ 1180 COL CENTRO...

Page 16: ...ILLAHERMOSA TAB C P 86010 CONMUTADOR 01 993 353 7244 In the event of any problem contacting a Service Center please see our webpage www truper com to get an updated list or call our toll free numbers...