INTRODUCTION.

Read carefully this Manual before operating or servicing this 

air compressor.  Get familiar with the right procedures for its 

safe operation and maintenance. Failure to observe the 

instructions in this Manual may result in personal injury as 

well as material damages and/or making the Warranty void.  

Following the instructions in this Manual will deliver to the 

compressor a longer and safer working life.

TECHNICAL CHARACTERISTICS:

Voltage:

 

 

120 V~

Frequency:    

 

60 Hz

Motor Rated Power:

 

1 Hp

Maximum Motor Power:

  2 Hp

Maximum Pressure:

 

116 PSI

Tank Capacity:

 

2.6 Gal

IP Grade:

  

IP20

Air Flow: 

 

3 CFM - 40 PSI

 

 

 

2 CFM - 90 PSI

Power Cord Grips Type:

 Y

All conductors are: 

16 AWG x 3 with 221 ºF insulating 

temperature 

Build quality: 

Basic insulation.

Insulation quality:

 Class I

Thermal insulation of motor winding:

 Class B

 

             

 To avoid risk of electrical shock or serious 

accident, if power cord gets damaged it should be repaired by 

the manufacturer or by Truper

®

 Authorized Service Center 

Power cord grips used in this product: Type”Y”.

Assembly design in this product causes insulation to be affected 

by liquid spills or splashing.

 

                             

Before gaining access to terminals,

 

  all power circuits should be disconnected.

 

                

            We do not recommend using power

 

  cord extensions with compressors.  Using that type of

 

  extension cause power drops resulting in motor 

potency loss and overheating.  Instead of using an extension 

cord increase the compressor’s action scope connecting a 

longer hose into the outlet. Connect additional hose lengths 

as needed.

SPECIFIC SAFETY GUIDELINES.

 

           THERE IS IMMINENT HAZARD OF SEVERE 

INJURY OR DEATH. TO REDUCE RISK OF FIRE OR 

EXPLOSION NEVER SPRAY FLAMMABLE LIQUIDS IN 

ENCLOSED AREAS.

1.   It is normal for the pressurestat to produce sparks while 

operating.  Should sparks come into contact with gasoline 

fumes or other solvents they could be ignited causing fire 

or explosion.  Always operate the compressor in a 

well-ventilated area.  Do not smoke while spraying.  Do 

not spray where open fire is present.  Keep the compressor 

as far away as possible from the spraying area.

2.   Solvents like Trichloroethane and Methylene Chloride may 

present a chemical reaction with aluminum used in a 

paint-spraying gun, paint pumps, etc., and may cause 

explosion.  Should you be using these types of solvents 

use only stainless steel spraying equipment: it will not 

affect the air compressor but could affect the equipment 

being used. 

3.   Never inhale compressed air produced by the compressor.  

It is not suitable as breathing air.

 

 

               POTENTIAL HAZARD OF SEVERE  

 

INJURY OR DEATH.

1.  Do not carry out welding jobs in the compressor air tank. 

An extremely dangerous condition may be created.  If 

carrying out any welding job on the tank the warranty will 

be void.

2.   Never use an electric air compressor outdoors when is 

raining or in wet surfaces. Hazard of electrocution!

3.   This unit starts automatically.  Always turn off the 

compressor.  Remove the plug from the power outlet and 

purge all pressure remaining in the system before servicing 

or when the compressor is idle.

4.   Double-check both the maximum pressure specified by 

the manufacturer and the pneumatic accessories.  The 

compressor exit pressure should be regulated to never 

exceed the maximum specified pressure.

5.   Under the unit’s cover there is high temperature as well 

as moving parts.  To prevent from burns or other hazards 

do not operate if the cover is not in place.  Allow the 

compressor to cool down before handling and servicing.

6.   Double-check you read the labels on paints or toxic 

materials you will spray.  Follow all safety rules.  Use a 

breathing mask if there is possibility of inhaling the sprayed 

material.  Read the instructions and make sure it gives the 

adequate protection.

7.   When using the air compressor always wear safety glasses 

or goggles.  Never aim the spraying nozzle towards other 

people or any part of the body.

8.   By no means adjust the pressurestat or relief valve.  It will 

make the warranty void.  Those devices are factory 

pre-adjusted to the maximum pressure for this unit.

 

 

                 POTENTIAL DANGER OF MODERATE  

 

INJURY OR DAMAGE TO THE UNIT.

1.   Drain periodically the humidity from the tank. A clean and 

dry tank will prevent corrosion.

2.   Pull daily the pressure relief valve rung to assure the valve 

is working correctly.  It also removes any obstruction from 

the valve.

3.   Provide adequate surrounding ventilation space to cool 

down the compressor.   It should sit approximately at 12” 

from the nearest wall and in a well-ventilated are.

4.   Securely fasten the compressor and release the tank 

pressure before transporting.

5.   Protect both air hose and power cable against damage or 

punctures.  Inspect weekly to detect weak or worn points.  

Replace if necessary.

APLICATION

Compressors are widely used with different tools as well as 

pneumatic tools in communications, machinery manufacturing, 

medical and health applications, garment manufacturing, 

spinning and weaving, wheels manufacturing, gas filling and 

paint.

OPERATION, LUBRICATION AND MAINTENANCE

1.   Please read carefully all technical documents after opening 

the packaging box (including the operation instructions).  

Double-check all parts are present and verify the 

compressor is not damaged.

2.   Verify oil level through the indicator spyhole set in the 

compressor rear side.  Should the oil level do not reach the 

middle (red circle), fill the deposit with SAE-30 motor oil until 

getting the right level.  Connect the power cable and operate 

compressor unloaded to verify is working correctly. (See 

figure 1)

3.   Connect the pneumatic tools and start the compressor in 

order to use them. (Note: The compressor should start with 

no load pressure). (See figure 2)

4.   The compressor works with SAE-30 lubricating oil. Fill with 

oil before operating. While running the oil temperature should 

be below 158 ºF. (See figure 1)

5.   After 5 hours operation, change oil and remove the casing 

cap. Wipe the dirty oil and other debris. Then, set the casing 

cap back and restart the air compressor.

 

                

Change oil every 150 working hours.

6.   Clean filter regularly once a week. (See figure 1).
7.   After 16 hours of operation open the purge valve below the 

tank, drain water from tank.  Clean the tank every six months. 

(See figure 4).

8.   After each use disconnect and release air pressure from the 

tank. (See figure 3)

9.   Service normally.  Disassemble the compressor and clean 

all its parts using light oil.  Wipe dry all parts.  When 

assembling, apply grease in all parts that are in contact.  

Repair or replace worn parts if necessary.  Assemble and 

adjust back all the parts.

10. When the compressor will not be used for a long period of 

time clean and grease all air valves and contact surfaces.

• The compressor has a thermal switch (See figure 5) that prevents 

the motor from overheating. The motor shuts off when the switch 

is activated. To re-establish the motor follow the following steps:

1.- Press the switch to ensure that the compressor is off.
2.- Let the compressor cool down for at least 5 minutes.
3.- Press the thermal switch located on the side of the crankcase.
4.- Lift the switch to start the compressor.

ACCESSORIES:

1 Oil Bottle
1 Filter
1 Oil Cap

NOTICE

3

READ INSTRUCTION MANUAL BEFORE OPERATING.

RISK OF ELECTRICAL SHOCK.

 Hazardous voltage, disconnect from power 

source before servicing, compressor must be grounded, do not expose to rain, 

store indoors..

RISK OF FIRE OR EXPLOSION.

 Do no spray combustible/flammable liquid 

in a confined area, spray area must be well ventilated, do not smoke while 

spraying or spray where spark or flame is present, arcing parts keep compressor 

at least 20 feet away from spraying area and all explosive vapors.

RISK OF INJURY. 

 Do not direct air stream at body, use eye protection 

compressor starts automatically, moving parts, do not touch keep guards in 

place, compressor does not supply breathable air.

       

RISK OF BURSTING.

 Do not adjust regulator to result in output pressure 

greater than marked maximum pressure of attachment, if a regulator has not 

been installed, use only attachment rated at 1 379 kPa (200 PSI) or higher, do 

not weld on or repair tank-replace. 

DISCONNECT POWER SOURCE BEFORE CLEANING THE AIR FILTER.

If connected to a circuit protected by fuses, use time-delay fuse marked “D”

Complies with IEC.

To reduce the risk of electric shock, do not expose to rain, store indoors.

LEA EL INSTRUCTIVO ANTES DE OPERAR.

RIESGO DE CHOQUE ELÉCTRICO.

 Tensión peligrosa: Desconéctelo del 

tomacorriente antes de darle servicio. El compresor se debe conectar a tierra, 

no use adaptadores para conectarlo a tierra. No lo deje a la intemperie, almacénelo 

bajo techo.

RIESGO DE INCENDIO O 

EXPLOSIÓN. No rocíe líquidos combustibles en un 

área cerrada. El área de trabajo debe estar bien ventilada, no fume mientras esté 

pintando ni rocíe cerca de chispas o llamas o piezas que produzcan arcos 

eléctricos, mantenga el compresor al menos a 6 m de distancia del área donde 

esté pintando o donde haya cualquier tipo de vapores explosivos.

RIESGO DE HERIDAS.

 No dirija el flujo del aire directamente al cuerpo, protéjase 

la vista, el compresor se enciende automáticamente, piezas que se mueven, no las 

toque, manténgalas protegidas. El compresor no le suministrará aire respirable.

RIESGO DE 

EXPLOSIÓN. No ajuste el regulador para obtener una presión de 

salida superior a la indicada como presión máxima del accesorio, si no ha instalado 

un regulador, use solo accesorios diseñados para presiones de 1 379 kPa (200 

PSI) o más, no suelde ni repare el tanque, reemplácelo.

DESCONECTAR DE LA RED ELÉCTRICA ANTES DE LIMPIAR EL FILTRO DE 

AIRE.

Si lo conecta a un circuito protegido con fusibles, use fusibles de acción retardada 

Tipo “D”
Cumple con las Normas IEC.

Para reducir el riesgo de descargas eléctricas no exponer a la lluvia.

ADVERTENCIA

ADVERTENCIA

WARNING

WARNING

ADVERTENCIA

Drene el tanque periódicamente

para evitar que se oxide

y el riesgo de heridas debido 

a un tanque dañado

WARNING

Drain tank periodically 

to prevent corrosion and 

possible injury due 

to tank  damage.

Oil Spyhole

Air Filter

Fig. 1

Oil Filling 

cap

Air Outlet

Fig. 2

Purge 

Faucet

Fig. 4

Security 

valve

Fig. 3

Thermal 

switch

Fig. 5

WARNING

Do not use or

start the compressor 

without oil.

WARNING

This unit SHOULD BE USED with

115 V˜ to 125 V˜  feeding tension.

Using a different TENSION WILL 

SEVERELY DAMAGE

the unit.

CONNECTION TO THE MAIN POWER SUPPLY

The compressor shall be set as close as possible to the main 

power supply.  Double-check the power supply matches the 

voltage indicated in the motor nameplate.

 

               

This unit must be grounded.

 

               

The power cables are coded with

the following colors:

GREEN AND YELLOW      GROUND

BLUE                                NEUTRAL

BROWN                            CURRENT

GROUND

CURRENT

WARNING
CAUTION

4 Rubber Supports

1 Bag with screws

This tool is in compliance with
the Official Mexican Standard
(NOM - Norma Oficial Mexicana).

Summary of Contents for COMP-10L

Page 1: ...digo 19215 NOTA IMPORTANTE Este producto no debe quedar expuesto a goteo o salpicaduras por l quidos Compresor de aire Instructivo Lea este Instructivo por completo antes de usar la herramienta ATENCI...

Page 2: ...na o se cruce cuando est en funcionamiento 12 No extienda su radio de acci n Evite toda postura que cause cansancio Cuide de que su posici n sea segura y de que conserve el equilibrio 13 Mantenga las...

Page 3: ...indicadora ubicada en la parte posterior del compresor Si el nivel de aceite no abarca el punto medio circulo rojo entonces llene el dep sito con INTRODUCCI N Lea este instructivo con atenci n antes d...

Page 4: ...t body use eye protection compressor starts automatically moving parts do not touch keep guards in place compressor does not supply breathable air RISK OF BURSTING Do not adjust regulator to result in...

Page 5: ...determinando porqu ocurri el problema 4 Oprima el bot n del interruptor t rmico para volver a restablecerlo 5 P ngase en contacto con un Centro de Servicio Autorizado Truper 1 Revise con un volt metr...

Page 6: ...NOTAS...

Page 7: ...SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZU IGA JAL TEL 01 33 3606 5285 AL 90 MICHOAC N FIX FERRETER AS AV PASEO DE LA REP BLICA 3140 A COL EX HACIEN...

Page 8: ...recomendadas o no se haya operado de acuerdo al instructivo o haya sido alterado o reparado por personal no autorizado por Para hacer v lida la garant a o adquirir piezas y componentes deber presenta...

Page 9: ...P 10L Code 19215 Air compressor Manual IMPORTANT NOTICE This product should not be exposed to liquids dripping or splashing Read the user s manual thoroughly before operating this tool CAUTION ENGLISH...

Page 10: ...ing one hand and enables to use both hands Keep proper footing and balance at all times Do not overreach over or walk across the tool when is running 12 Do not extend your range of action Avoid a stan...

Page 11: ...AL HAZARD OF SEVERE INJURY OR DEATH 1 Do not carry out welding jobs in the compressor air tank An extremely dangerous condition may be created If carrying out any welding job on the tank the warranty...

Page 12: ...essure greater than marked maximum pressure of attachment if a regulator has not been installed use only attachment rated at 1 379 kPa 200 PSI or higher do not weld on or repair tank replace DISCONNEC...

Page 13: ...e connection SOLUTION 1 Is it connected Check fuse circuit breaker 2 Replace blown fuse 3 Restart and determine what caused the problem 4 Push the thermal button to restart 5 Contact a Truper Authoriz...

Page 14: ...NOTES...

Page 15: ...GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZU IGA JAL TEL 01 33 3606 5285 AL 90 MICHOAC N FIX FERRETER AS AV PASEO DE LA REP BLICA 3140 A COL EX HACIENDA DE LA...

Page 16: ...60 CDMX Mex or at the store where you bought it or at a service center listed in the attached warranty policy and or at www truper com Transportation costs resulting from compliance of this warranty w...

Reviews: