TruSteel AutoVap30 User Manual | | v. 1.9
20 / 39
Go to PUMP CONTROL screen. Locate FEED PUMP section. Locate AUTO
SETPOINTS >PSI SETPOINT. Press on the PSI SETPOINT number and enter in your desired
PSI SETPOINT.
Normal operating PSI is between 30-60 PSI. Once you are in this range, the AutoVap is
now operational.
7.
After recovering a small amount of crude in the evaporator, press on the pump control
page, find the residue pump and manual override section at the bottom. Press "disabled"
and it will change to "enabled". Press start, discharge crude until empty and press stop.
Pour that crude oil back into the feed tank.
8.
Now press the "enabled" button to change it back to "disabled". Go back to the home page
and continue operation
Note: Now this will ensure to give you an accurate result of how the AutoVap is performing.
You can then fine tune the AutoVap as needed.
IMPORTANT:
Now you will need to PRIME THE DISCHARGE PUMPS.
SECTION V: RECYCLE MODE
When you run out of tincture or you are done processing for the day,
youʼll need to put the
AutoVap into recycle mode to drain the remaining tincture in the preheater.
This procedure is typically performed before and after CLEAN MODE.
Recycle Mode Explained
Recycle Mode is necessary in order to completely discharge the AutoVap30 of tincture (feed
material) that is still trapped in the system. Specifically, tincture gets trapped in the Preheater
after Auto Recovery has stopped.
Recycle Mode works by switching the direction of the Recycle Valve and the direction of the
Feed Pump. Now, instead of feeding the system with material from you reservoir, the system
will drain the PreHeater of all material, feed it through the Feed Pump, through the Recycle Valve,
up to the sprayer and will recover this last amount of solvent/crude material.
Recycle Mode is important for 2 reasons.
1. Reduce wasted material: There may still be a few liters of material in the preheater. Over
time, this small amount can add up. You do not want to waste this material by running clean
mode right through it.
2. Clear the preheater for cleaning mode. It is ideal to have the preheater clear of any tincture
before running clean mode. This ensures you are getting a full cleaning of the preheater without
the interference of tincture.
RUN RECYCLE MODE
Procedure
1. STOP FEED PUMP
If you haven't already, press STOP on the feed pump so the AutoVap is not running.
2. CLOSE FEED LINE
Summary of Contents for AutoVap30
Page 1: ...Copyright 2020 by TruSteel LLC All Rights Reserved TruSteel AutoVap30 User Manual Version 1 9 ...
Page 3: ...TruSteel AutoVap30 User Manual v 1 9 3 39 STEP 8 SHUT DOWN 39 ...
Page 5: ...TruSteel AutoVap30 User Manual v 1 9 5 39 ...
Page 6: ...TruSteel AutoVap30 User Manual v 1 9 6 39 ...
Page 7: ...TruSteel AutoVap30 User Manual v 1 9 7 39 ...
Page 36: ...TruSteel AutoVap30 User Manual v 1 9 36 39 AV30 FLOW IMAGE CUTAWAY CLICK HERE FOR LARGER VIEW ...