TruSteel AutoVap30 User Manual | | v. 1.9
24 / 39
STAGE 3: SOLVENT CLEANING CYCLE 2
REPEAT THE SOLVENT CLEANING MODE USING 3-
4 GALLONS OF SOLVENT
This step will remove any residual water left in the system from
the DISTILLED WATER CLEANING CYCLE.
STAGE 4: COMPLETING CLEAN MODE
MANUAL DISCHARGE
Put the RESIDUE PUMP into MANUAL OVERRIDE
Start the RESIDUE PUMP to manually discharge all cleaning solvent
Your AutoVap is now clean and ready to either be run again, or shut down.
SECTION VII: SHUT DOWN
IMPORTANT! Before SHUT DOWN, make sure the
AutoVap was run through CLEAN MODE.
Failure to perform CLEAN MODE before shutting
down the AutoVap could cause clogs in the system
and could cause pump failure when restarting the
AutoVap system. Failure to run CLEAN MODE could
void warranty on the system.
SHUTTING DOWN AUTOVAP SYSTEM
Procedures
1. TURN OFF HMI
Locate the red button on the HMI and push it
“IN” to turn off the HMI.
2. CLOSE FEED LINE
Locate the ball valve on the feed line and close it.
3. TURN OFF WATER HEATER RECIRCULATING PUMP
Locate the power switch for the water heater recirculating pump and switch it off.
This will essentially turn off the water heater by not allowing any flow to trigger the water
heater sensor.
Operators can also turn off the water heater disconnect (optional).
4. TURN OFF VACUUM PUMP
Locate the power switch for the vacuum pump and turn off.
If vacuum pump is only plugged in, either remove plug, or power vacuum pump off at the
unit itself.
5. PUT CHILLER IN STANDBY MODE
Summary of Contents for AutoVap30
Page 1: ...Copyright 2020 by TruSteel LLC All Rights Reserved TruSteel AutoVap30 User Manual Version 1 9 ...
Page 3: ...TruSteel AutoVap30 User Manual v 1 9 3 39 STEP 8 SHUT DOWN 39 ...
Page 5: ...TruSteel AutoVap30 User Manual v 1 9 5 39 ...
Page 6: ...TruSteel AutoVap30 User Manual v 1 9 6 39 ...
Page 7: ...TruSteel AutoVap30 User Manual v 1 9 7 39 ...
Page 36: ...TruSteel AutoVap30 User Manual v 1 9 36 39 AV30 FLOW IMAGE CUTAWAY CLICK HERE FOR LARGER VIEW ...