TruSteel AutoVap30 User Manual | | v. 1.9
30 / 39
clears before the Alarm can be reset than the Alarm indication will clear itself.
·
Feed Outlet Temperature
: If Enabled an Alarm Indication will be initiated for this if the
temperature drops below the alarm setpoint for the preset amount of time. If the condition
clears before the Alarm can be reset than the Alarm indication will clear itself.
·
Filter Clog
: If Enabled an Alarm Indication will be initiated for this during automatic control
if the speed command output is above the alarm setpoint for the preset amount of time. If
the condition clears before the Alarm can be reset than the Alarm indication will clear
itself.
Note***Extraction Mode normally will operate between 20 PSI- 60 PSI
ALARMS 2
·
Vacuum Pressure
: If Enabled an Alarm Indication will be initiated for this if vacuum
pressure goes above the High alarm setpoint or goes below the Low alarm setpoint for the
preset amount of time. If the condition clears before the Alarm can be reset than the Alarm
indication will clear itself.
·
PreHeater
: Pressure Alarm- If Enabled an Alarm Indication will be initiated for this if
preheater pressure goes above the High alarm setpoint or goes below the Low alarm
setpoint for the preset amount of time. If the condition clears before the Alarm can be reset
than the Alarm indication will clear itself.
·
Condenser Outlet Temp Alarm
: If Enabled an Alarm Indication will be initiated for this if
the temperature rises above the High alarm setpoint or goes below the Low alarm setpoint
for the preset amount of time. If the condition clears before the Alarm can be reset than the
Alarm indication will clear itself.
·
Residue Pump Fail to Run
: If Enabled an Alarm Indication will be initiated for this if the
pump fails to provide running feedback in the preset amount of time after being called by
the PLC. If the condition clears before the Alarm can be reset than the Alarm indication will
clear itself.
·
Feed Pump Fail to Run
: If Enabled an Alarm Indication will be initiated for this if the pump
fails to provide running feedback in the preset amount of time after being called by
the PLC. If the condition clears before the Alarm can be reset than the Alarm indication will
clear itself.
·
Ethanol Pump Fail to Run
: If Enabled an Alarm Indication will be initiated for this if the
pump fails to provide running feedback in the preset amount of time after being called by
the PLC. If the condition clears before the Alarm can be reset than the Alarm indication will
clear itself.
·
Residue High Switch Alarm
: If Enabled an Alarm Indication will be initiated for this if the
feed pump is running and if the High Residue Switch is made up preset amount of time.
Alarm Rest is required for alarm indication to clear itself.
·
Ethanol High Switch Alarm
: If Enabled an Alarm Indication will be initiated for this if the
feed pump is running and if the High Ethanol Switch is made up preset amount of time.
Alarm Rest is required for alarm indication to clear itself.
During Extraction mode if the H-O-A in the field are in Auto, then Control through HMI can be
initiated. If there are currently no lockouts then, initiating
“Start” pushbutton on the Feed pump will
start the pump ramp up to the desired pressure. After preheater pressure rises past the
“PSI
Setpoint
” in the “Pump Control” screen than it automatically switches over to PID control. This
control allows the user to input a desired pressure and have the algorithm automatically correct
the Feed Pump Speed to maintain the pressure at the PSI Setpoint. After starting up there are
multiple lockouts on Feed Pump that will stop feed operation, which are
1. Vacuum Lockout
2. Evap Lockout
3. Cond Lockout
4. Over Speed Lockout
Summary of Contents for AutoVap30
Page 1: ...Copyright 2020 by TruSteel LLC All Rights Reserved TruSteel AutoVap30 User Manual Version 1 9 ...
Page 3: ...TruSteel AutoVap30 User Manual v 1 9 3 39 STEP 8 SHUT DOWN 39 ...
Page 5: ...TruSteel AutoVap30 User Manual v 1 9 5 39 ...
Page 6: ...TruSteel AutoVap30 User Manual v 1 9 6 39 ...
Page 7: ...TruSteel AutoVap30 User Manual v 1 9 7 39 ...
Page 36: ...TruSteel AutoVap30 User Manual v 1 9 36 39 AV30 FLOW IMAGE CUTAWAY CLICK HERE FOR LARGER VIEW ...