TruSteel AutoVap30 User Manual | | v. 1.9
39 / 39
2. Press EXTRACTION MODE under "System Mode". You are now in RECYCLE MODE
The Recycle Valve will rotate to ON position. (Wait until it completes
VALVE IN MOTION
)
3.
START FEED PUMP
Wait for the atomizer/preheater pressure to stabilize and adjust the speed (if
needed)
Look for the recycle mode setpoints to adjust. Match the same pressure you have been
extracting at.
4. DRAIN RESIDUE FROM SYSTEM
Put the RESIDUE PUMP into Manual Override Mode and manually discharge the residue
material from the system.
STEP 7: CLEANING CYCLE
1. Press
“Enable” on “Clean Mode”.
2. Set Vacuum close to atmospheric PSIA (may vary on your altitude)
3. CLEAN SOLVENT
Run clean solvent until the solvent looks clear in the residue sightglass.
Collect tainted solvent.
Run Recycle Mode....manually discharge.
4. DISTILLED WATER.....VERY IMPORTANT STEP!
Run distilled water through system and then discharge.
Run Recycle Mode...manually discharge.
5. Run more clean solvent through system.
Note: This solvent will have water in it and you may not want to reuse it.
Run Recycle Mode...manually discharge.
6. Manually Discharge all solvent from system.
STEP 8: SHUT DOWN
1. Close Feed Valve
2. Turn off HMI
3. Turn off Vacuum. Leave Vacuum Valve open.
4. Turn off water heater recirculating pump.
5. Put Chiller in Standby Mode
Summary of Contents for AutoVap30
Page 1: ...Copyright 2020 by TruSteel LLC All Rights Reserved TruSteel AutoVap30 User Manual Version 1 9 ...
Page 3: ...TruSteel AutoVap30 User Manual v 1 9 3 39 STEP 8 SHUT DOWN 39 ...
Page 5: ...TruSteel AutoVap30 User Manual v 1 9 5 39 ...
Page 6: ...TruSteel AutoVap30 User Manual v 1 9 6 39 ...
Page 7: ...TruSteel AutoVap30 User Manual v 1 9 7 39 ...
Page 36: ...TruSteel AutoVap30 User Manual v 1 9 36 39 AV30 FLOW IMAGE CUTAWAY CLICK HERE FOR LARGER VIEW ...