TruSteel AutoVap30 User Manual | | v. 1.9
22 / 39
After running RECYCLE MODE...
1. 1st SOLVENT CLEANING
Solvent cleans the oil out of the AutoVap.
2. DISTILLED WATER CLEANING
Distilled water cleans plants sugars and gums that are left behind.
3. 2nd SOLVENT CLEANING
This solvent clears out the residual water from the AutoVap.
Note: Make sure to run RECYCLE MODE and manually discharge after each stage. This will
clear the preheater and the residue discharge sight glass after each stage.
CLEANING CYCLE PREPARATION
PREPARE CLEANING SOLVENTS
1.
Prepare 5-10 gallons of clean solvent to run the solvent cleaning cycle on the AutoVap
system.
This should be the same solvent you are using in your extraction process.
2.
Prepare 4-8 gallons of distilled water to run after the solvent is ran through the AutoVap
system.
3.
Prepare 2 additional containers to collect the tainted solvent or tainted distilled water.
PREPARE AUTOVAP FOR CLEANING CYCLE
1.
Attach/Place feed line into the clean solvent or distilled water.
2.
Close the BLUE feed line ball valve.
3.
Locate the area on the HMI Home Screen where it says
“system mode”
The current system mode should say
“Extraction”
If not, press on the
“Recycle” button and the system will switch back to “Extraction” mode.
4.
Locate the area on the HMI Home Screen where it says
“Clean Mode”.
5.
Press
“Enable” on “Clean Mode”.
By enabling
“Clean Mode”, lockouts on the pump control page will be disabled. You will
now be able to raise the vacuum pressure to allow you to clean the evaporator.
STAGE 1: SOLVENT CLEANING CYCLE
STEP 1: CLEAN MODE PUMP SPEED
1.
Locate the
“Feed Pump” settings on the HMI Home Screen and press “Start”.
2.
Locate
“Clean Mode” and look for “Speed”
The feed pump will quickly ramp up to the
“clean mode speed”.
The
“clean mode speed” adjusts the speed of the motor (measured in Hz), which also
changes the
“Preheat pressure”.
Be sure not to adjust the
“clean mode speed” too high. (15-25 Hz is sufficient)
Adjust the speed in small increments and watch the preheat pressure raise between 50-
60 PSI for cleaning.
Summary of Contents for AutoVap30
Page 1: ...Copyright 2020 by TruSteel LLC All Rights Reserved TruSteel AutoVap30 User Manual Version 1 9 ...
Page 3: ...TruSteel AutoVap30 User Manual v 1 9 3 39 STEP 8 SHUT DOWN 39 ...
Page 5: ...TruSteel AutoVap30 User Manual v 1 9 5 39 ...
Page 6: ...TruSteel AutoVap30 User Manual v 1 9 6 39 ...
Page 7: ...TruSteel AutoVap30 User Manual v 1 9 7 39 ...
Page 36: ...TruSteel AutoVap30 User Manual v 1 9 36 39 AV30 FLOW IMAGE CUTAWAY CLICK HERE FOR LARGER VIEW ...