Status Light Indicator 

During operation the status light located on the skylight motor cover 
will be steady green to indicate normal operation.  (See “Status 
Codes”
 on page 25 for more information.) 

 

 
From the optional wall switch control: 

 

To open the skylight: 

  Press skylight “Open” button. 

Note: The full open position varies with operating hardware and 
curb height of the skylight.  The typical stop position is approx. 90% 
of full open. 

 

To close the skylight: 

  Press skylight “Close” button. 

 

For an intermediate open position,  

  Press the “opposite” function while the motor is running - the motor 

will stop in that position. 

 

Status Light Indicator 

During operation the status light located in the skylight motor and on 
the switch face plate will be steady green to indicate normal operation.  
(See “Status Codes” on page 25 for more information.) 

 

 
Note: 
 Any time there is a power outage, the skylights will automatically 

close when power is restored.  The system is programmed this way 
because the system will not recognize any attempts to open or close 
the skylight while the power is off including attempts by the rain sensor 
(if installed) to close.  Therefore, the safest position for the skylight to 
be in when power is restored is closed.  All controls will return to 
normal function once power is restored.  

 
Buttons located on wall switch: 

 

 

 
 
 
 
 
 
 
 

Status 

Light 

Open 

Skylight 

 

Close 

Skylight 

 

Open 

Blind 

Close 

Blind 

Summary of Contents for Sentry II

Page 1: ...and Spanish versions available at www truth com technicalsupport HS Skylight Motorization System Installation Instructions Made in USA An FKI Industries Company 700 West Bridge Street Owatonna MN 550...

Page 2: ...MUST be correctly installed and is a required part of the power skylight system It is intended to help prevent injury that could result from reaching into the skylight area during operation The corre...

Page 3: ...installation 8 Screen Interlock 11 Normal operation 14 Battery backup 16 Wall mounted switch panel 17 Rain sensor 17 HPI 19 Status feedback 20 Power blind control 20 General trouble shooting 22 DIP sw...

Page 4: ...e range must be maintained between 140 F 60 C to 5 F 20 C Single motor vs multiple synchronous motor application Most applications of the Sentry II HS system will be a single motor on a single skyligh...

Page 5: ...12473 92 6 Chain 11533 7 Sprocket 30654 8 Terminal block 9 Strain Relief Items 8 thru 9 are part of 10 Screen Interlock hardware kit 12482 11 Rain sensor 12 Screws 4 Size A 12 24 X 5 8 TF Ph FH self t...

Page 6: ...to install the rain sensor each control unit needs a separate rain sensor Consult main wiring diagram for wiring requirements o Power mini blinds The Sentry II control unit is capable of controlling...

Page 7: ...Did you find what you re looking for The Truth Hardware Web site is a great resource for the latest product and installation information It s available at www truth com 7 Main wiring diagram...

Page 8: ...ver 80 lbs or wider than 40 refer to the Synchronous Motor section of the manual 2 Install Chain Base Remove existing manual operator and or chain base if present Install the chain base included with...

Page 9: ...y power must be off until instructed to turn it on Remove high voltage protection cover Install Hit Loc strain relief as shown Route 120 VAC supply wiring through the rear inlet and strain relief on c...

Page 10: ...rive sprocket Once the motor is fully engaged with the chain base the control box is effectively locked into the chain base motor drive assembly Secure with 4 12 24 X 5 8 Ph FH Machine Screws in the l...

Page 11: ...of the screen interlock is the responsibility of the installer Screen interlock installation Install screen interlock to the screen frame as shown below using 6 32 X 3 8 Phillips PH Self Threading Ma...

Page 12: ...ocation and into control board opening Connect low voltage wires to the control panel as outlined for each accessory Accessories and other control options are wired to the motor designated as the Lead...

Page 13: ...r trim button 6 32 X 3 8 Phillips PH Self Threading Machine Screw WARNING Use of a longer screw will damage motor If needed a spare screw is supplied in the hardware pack 10 Power Up and Initializatio...

Page 14: ...tablish its operating parameters which will be stored in permanent memory Once permanent memory is established it is unaffected by loss of power of any duration 11 Program Remote Control If a remote c...

Page 15: ...position Press the opposite function while the motor is running the motor will stop in that position Status Light Indicator During operation the status light located in the skylight motor and on the...

Page 16: ...are primarily used to supply emergency backup for computer equipment Truth Hardware is not a supplier of battery back up systems To determine the proper VA rating for a UPS take 50 watts and multiply...

Page 17: ...e cover plate can however be painted or wall paper can be applied to change its appearance Rain Sensor included The sensor will close the skylight when beading moisture is present on the surface of th...

Page 18: ...r shielded twisted pair 50 ft 15m maximum length Important Connect shield to earth ground to reduce interference from lightning and other electrical devices The sensor can be installed outside maximum...

Page 19: ...eact A contact closure of 3 seconds is needed to activate a close command Input Function HPI Open 1 When connected by a continuous contact closure the skylight will fully open All other input devices...

Page 20: ...contacts open the skylight is not fully closed Feedback output contact closure maximum ratings Rated Load 0 50 A at 125VAC 1 A at 24VDC Minimum Load 1mA 5VDC Max operating voltage 125 VAC 60 VDC Max o...

Page 21: ...ble to determine the positive wire to open the motorized blind the blind motor can be connected in either orientation However if the blinds open in the opposite direction from the button pressed the t...

Page 22: ...tions supplied with the wall switch unit Skylight does not open fully The motor system is programmed to only open a skylight to 90 of full opening This is done to protect the hardware from repeated hi...

Page 23: ...f the power is not disconnected the DIP switch change may not be recognized System Reset There are times when the motor system operating characteristics can change This can occur for a number of reaso...

Page 24: ...reapply With the skylight closed simultaneously press both the skylight and blind close buttons When the status light turns red release the buttons The skylight will cycle open and then close Through...

Page 25: ...uring setup and operation the status light on the skylight motor and switch panel if installed will provide information regarding system function The following list will help explain the different con...

Page 26: ...Flashing Green 1 Under normal operation it indicates the rain sensor has been activated The light will flash green only while the skylight is closing 2 Indicates set up mode for the hand held remote S...

Page 27: ...ting Truth Hardware please be aware that Complete product and troubleshooting information is available on our web site at www truth com technicalsupport A qualified electrician is required to resolve...

Page 28: ...the latest product and installation information It s available at www truth com 28 Non Synchronous Operation To connect multiple motors on different skylights together none can be on synchronous syst...

Page 29: ...switch connection HPI connections or remote Learn procedure only happens to the Leader of the group 1 Verify Skylight Weight Important Skylight Information The skylight lid weight must not exceed 200...

Page 30: ...Did you find what you re looking for The Truth Hardware Web site is a great resource for the latest product and installation information It s available at www truth com 30...

Page 31: ...aler or an experienced radio TV technician for help Warning Changes or modifications not expressly approved by Truth Hardware could void the FCC compliance and negate your authority to operate the pro...

Page 32: ...An FKI Industries Company 700 West Bridge Street Owatonna MN 55060 www truth com...

Reviews: