background image

2

 

 

 

TRU

WELD

 

EQUIPMENT

 

LIMITED

 

WARRANTY

 

All

 

goods

 

produced

 

by

 

Truweld

 

Equipment

 

shall

 

be

 

warranted

 

against

 

defects

 

including

 

workmanship

 

and

 

components.

 

No

 

other

 

war

ranties

 

whether

 

expressed,

 

verbal,

 

or

 

implied

 

will

 

apply.

 

Warranties

 

only

 

apply

 

to

 

the

 

original

 

equipment

 

purchaser.

   

Warranty

 

claims

 

will

 

be

 

limited

 

to

 

either

 

repair

 

or

 

replacement

 

of

 

the

 

defective

 

materials

 

by

 

Truweld

 

Equipment.

 

At

 

the

 

option

 

of

 

Tru

weld

 

Equipment

 

the

 

location

 

of

 

where

 

the

 

warranty

 

evaluation

 

and

 

repairs

 

are

 

made

 

will

 

be

 

determined.

 

All

 

warranty

 

claim

 

items

 

re

turned

 

to

 

Truweld

 

Equipment

 

will

 

be

 

at

 

the

 

customer’s

 

expense.

 

At

 

the

 

option

 

of

 

Truweld

 

Equipment

 

the

 

defect

 

will

 

either

 

be

 

repaired

 

or

 

replaced.

 

Notice

 

must

 

be

 

provided

 

to

 

Truweld

 

Equipment

 

of

 

a

 

warranty

 

defect

 

within

 

30

 

days

 

that

 

the

 

defect

 

or

 

failure

 

is

 

incurred.

 

Warranties

 

are

 

not

 

transferable.

  

This

 

warranty

 

does

 

not

 

apply

 

for

 

equipment

 

which

 

is

 

used

 

improperly

 

in

 

any

 

fashion

 

including

 

but

 

not

 

exclusive

 

to

 

the

 

following:

 

Equipment

 

which

 

has

 

been

 

modified

 

Equipment

 

which

 

has

 

not

 

been

 

installed

 

properly

 

Equipment

 

which

 

has

 

been

 

used

 

for

 

purposes

 

other

 

than

 

which

 

it

 

had

 

been

 

designed

 

Equipment

 

which

 

has

 

not

 

been

 

properly

 

maintained

 

Equipment

 

which

 

was

 

continued

 

to

 

be

 

used

 

after

 

a

 

defect

 

had

 

been

 

found

 

Equipment

 

which

 

was

 

damaged

 

in

 

any

 

way

 

Truweld

 

Equipment

 

will

 

never

 

be

 

liable

 

for

 

consequential

 

damages,

 

loss,

 

or

 

expense

 

occurring

 

directly

 

or

 

indirectly

 

from

 

the

 

use

 

of

 

the

 

equipment

 

covered

 

in

 

this

 

warranty.

 

All

 

cables,

 

cable

 

sets

 

and

 

connectors

 

are

 

not

 

warranted.

 

 

Two

 

(2)

 

year

 

warranty

 

period

 

from

 

date

 

of

 

purchase

 

 

TWE250

 

Power

 

Supply

 

SC1900

 

Power

 

Supply

 

 

TWE321

 

Power

 

Supply

 

SC1950

 

Power

 

Supply

 

 

TWE375

 

Power

 

Supply

 

SC2400

 

Power

 

Supply

 

 

SC900

 

Power

 

Supply

 

SC2402

 

Power

 

Supply

 

 

SC1400

 

Power

 

Supply

 

SC2420

 

Power

 

Supply

 

 

SC1450

 

Power

 

Supply

 

SC3400

 

Power

 

Supply

 

 

SC1600

 

Power

 

Supply

 

SC3402

 

Power

 

Supply

 

 

SC1650

 

Power

 

Supply

 

 

One

 

(1)

 

year

 

warranty

 

period

 

from

 

date

 

of

 

purchase

 

 

 

TWESPC

 

Power

 

Supplies

 

 

 

TWP

2

     

Power

 

Supply

 

 

Ninety

 

Day

 

(90)

 

warranty

 

period

 

from

 

date

 

of

 

purchase

  

 

        

(Excluding

 

cables

 

and

 

connectors)

 

 

 

TWE70000

 

HD

 

Arc

 

stud

 

gun

 

 

 

TWE18500

 

MD

 

Arc

 

stud

 

gun

 

 

 

TWE19000

 

LD

 

Arc

 

stud

 

gun

 

 

 

TWEG

 

CD

 

stud

 

gun

 

 

 

TWEHDG

 

Heavy

 

Duty

 

CD

 

stud

 

gun

 

Summary of Contents for TWE - SC2402

Page 1: ...m http truweldstudwelding com Operations Manual The SC2402 is a fully integrated stud welding system with two digital con trols for time and current The system was designed to meet the most challenging stud welding jobs to include weld thru deck applications TWE SC2402 Heavy Duty Stud Welding System Version 3 0 08 14 2013 ...

Page 2: ...ch has been modified Equipment which has not been installed properly Equipment which has been used for purposes other than which it had been designed Equipment which has not been properly maintained Equipment which was continued to be used after a defect had been found Equipment which was damaged in any way Truweld Equipment will never be liable for consequential damages loss or expense occurring ...

Page 3: ...ns 11 6 4 SC2402 Setup and Installation Control Cable Connections 12 7 0 SC2402 Operations Stud Gun Setup 7 1 Stud Gun Setup Initial Steps 13 7 2 Stud Gun Setup Lift Adjustment 14 7 3 Stud Gun Setup Plunge Adjustment 15 7 4 Stud Gun Setup Cable Connections 16 8 0 SC2402 Operations Settings 8 1 SC2402 Operations Unit Power Diagnostic Lights 17 8 2 SC2402 Operations Setting Time and Current 18 8 3 S...

Page 4: ... improvement Our long standing relationship with our customers and suppliers is our key to contin ued success and growth If we can be of any further assistance to you and your company please do not hesitate to contact us Product Information The SC2402 is a fully integrated stud welding system with two digital controls for time and current The system was designed to meet the most challenging stud w...

Page 5: ... designed and built with operator safety in mind but safety begins with you Every effort has been made to protect the trained operator from injury Please become familiar with the information in this manual to minimize the risk of shock or injury STUD WELDING CAN BE HAZARDOUS ALWAYS PROTECT YOURSELF AND OTHERS FROM POSSIBLE INJURY OR DEATH KEEP CHILDREN AWAY Operators who have a pacemaker should co...

Page 6: ...ine before moving a welding power source Always be sure the work cable makes a good electrical connection with the metal being welded The connection should be as close as possible to the area being welded Turn OFF welding power source before servicing unless the procedure specifically requires an energized unit Never touch the energized stud or gun before discharging the stud to ground Never use t...

Page 7: ...o the area being welded Keep welding power source and cables as far away from your body as possible Electromagnetic fields can irrevocable erase magnetic data carriers computer memory credit cards security ID cards or data storage diskettes Electromagnetic fields may magnetize and damage watches or similar digital devices PROTECT YOURSELF and OTHERS Some welding cutting and gouging processes are n...

Page 8: ...Counter that can be reset for every job or project On Demand Fan that cycles on and off when needed Weld Range 1 4 to 1 1 4 Consistent welding regardless of stud diameter Duty Cycle 1 4 thru 5 8 3 4 7 8 1 Unlimited 18 to 24 per minute 12 to 14 per minute 6 to 8 per minute Dimensions Height Width Length Weight 28 736 6mm 29 711 2mm 36 914 4mm 760 Lbs 345kg Input Voltages 380 400 VAC 3 Phase 50Hz Fu...

Page 9: ...king materials that may obstruct airflow through the welder If the equipment is not being installed immediately store it in a clean dry well ventilated area until in stallation Selecting a Location The location of the power source should be carefully selected to ensure satisfactory and depend able service Choose a location relatively close to a properly fused source of electrical power Use care ag...

Page 10: ...rough the Power Inlet Hole in the top left corner on the backside of the welder Connect the power leads Black White Red to the L1 L2 and L3 connectors as shown in Fig ure 1 Firmly tighten screws that hold the power leads in place Attach the ground wire Green to side bracket of welder as shown in Figure 1 Once the Primary Power Cable is connected tighten Power Cable Clamp on the back of the welder ...

Page 11: ...tions located in the front of the welder lift access panel Tighten ground cable to welder and secure other end to work surface using the Heavy Duty C Clamp see Figure 2 Ground Cable Lug to welder Ground Cable C Clamp to work surface Figure 2 Ground Cable Access Panel Ground connections Figure 1 Front of SC2402 ...

Page 12: ...elder Plug Control Cable plug into port on bottom front of welder lift access panel The Control Cable has a male 4 pole connector on one end that plugs into the port After the cables are connected to the welder it is time to configure your weld gun for its specific job Once the gun is configured and set up properly the gun cables will connect to the weld cables For the SC2402 the weld cable ends t...

Page 13: ...e stud to be welded After all of the proper accessories have been mounted on the stud gun place the stud in the chuck and begin the alignment of the accessories Make certain that a sufficient amount of the stud is inserted in the chuck so that the stud is held firmly Attach the ferrule to the ferrule grip Plunge setting move the leg foot and ferrule assembly so that the stud protrudes beyond the f...

Page 14: ...anging in diameter through 3 4 this adjustment should be suitable For larger diameter studs and select applications the lift should be adjusted to approximately 1 8 Adjusting the lift Remove the back cap of the stud gun Loosen the two socket set screws around the periphery of the lift adjustment screw To increase lift rotate the lift adjustment screw counter clockwise and to decrease lift rotate c...

Page 15: ... which the stud is plunged into the molten weld pool by moving the engagement point of when the shaft of the stud gun engages the damp ener Rotating the dampener cover counter clockwise increases the amount of free travel Dampener Cover TWE17000 Heavy Duty Weld Gun TWE18500 Medium Duty Weld Gun ...

Page 16: ...it and actuate the stud gun Make sure welder is set up properly to begin the welding process Place the selected stud into the chuck and attach the ferrule to the ferrule grip Place stud onto surface to be welded and press stud gun down until ferrule is flush with the welding surface Trigger the gun and hold in place until cycle is completed Pull gun assembly straight up off of the welded stud Do n...

Page 17: ...hat there is a good connection SC2402 Diagnostic Lights On the Control Panel located below the digital display is a row of diagnostic lights for the welder OUTPUT When the stud gun is triggered this light comes on to indicate that the OCV is present at the output terminals TRIGGER When the stud gun is triggered this light comes on to indicate that the trigger circuit is functioning properly and th...

Page 18: ...te time or current this will toggle be tween 10th s and 100th s of a unit seconds or amps depending on whether you are setting Time or Current There is a Chart see below of approximate settings for full base diameter studs located to the left of the Controls Time Button Adjustment Dial Current Button Fine Coarse Switch Digital Displays DIA INCH TIME SEC AMPS DC DIA DEC DIA MM 1 4 0 200 500 250 6 3...

Page 19: ...ng total of the number of welds since the counter was last reset To view the job counter set the Fine Coarse Switch to the Fine position Each weld will be recorded on the Current digital display If the switch is in the Coarse position the weld will still be counted but will not be displayed You can also view the Job Counter total by depressing the Adjustment Dial while the switch is in the Coarse ...

Page 20: ...pring plunges the weld stud down into the molten pool of metal in the base material The cycle is completed in less than a second and the resulting weld bond develops the full strength of the fastener in the weld zone Allow metal to cool and withdraw gun from the stud pulling the gun straight up off of the stud The weld gun is withdrawn from the weld stud leaving and the ferrule The ferrule is brok...

Page 21: ...st the welds at the beginning of each shift or change in stud Bend two studs 30 degrees af ter cooling AWS Bend Test Check burn off 1 8 3 16 color silver blue and shiny and weld fillet 360 degree Visually inspect all welds Thru Deck Stud Welding Helpful Hints and Suggestions Keep weld studs and ferrules clean and dry Never attempt thru deck welding when the ambient temperature is below 32o F Deck ...

Page 22: ...ms a bumpy or jagged collar around the base of the weld stud This normally occurs when the weld time is set too high Porous Weld Collar This usually occurs from the oxidation of the weld pool resulting from the weld time being set too long and or the current being too low Reduce the current and or reduce the weld time to correct Weld Collar Off Center This is when the collar is heavy or thick on o...

Page 23: ... on control panel responds 4 Check to see if weld tool is wired according to one of the three diagrams in Chart A see page 25 5 Locate Touch Trigger Control Board 16002 Chart B Check and note the operation of the driver LED s and report the status Unit turns on no coil test no lift from gun coil trigger is good Bad connection or faulty equipment 1 Test control cable by plugging weld tool directly ...

Page 24: ...d connections in cluding grounds 3 Test the power loop by making welds on a test piece us ing only the starter cable set 4 Test 3 phase power to control contactor 5 Check taps if applicable on main transformer Weld gun lifts but does not plunge Gun maintenance If this happens it is most likely binding inside of the gun Per form routine gun maintenance or replace gun if needed All tests should be p...

Page 25: ...d Equipment Digital Series Welders will accept any one of these configurations without changing any wiring in the machine When making your own tool extensions 16 4 cable is recommended NOTE Make sure the ground pin is isolated from the case Contact Tru Weld Equipment with any questions on connections ...

Page 26: ...1 Active LED 3 L3 15Vdc LR6 PA L2 WORK LR3 GUN C A GREEN Pos 15V Supply D1 Pilot Arc Output Stud On Work Indicator GC FUSE Indicator Channel A Selected LED 4 L4 15Vdc LR4 COIL L3 TRIG LG2 GUN P B GREEN Neg 15V Supply BR1 2 Output Trigger Indicator GHV Signal Channel B Selected LED 5 LG1 PAph2 L5 2WIRE LR2 GUN P RED Q2 Drive Signal Input 2 Supply GP FUSE Indicator TR2 Active LED 6 LR5 PAph1 L4 4WIR...

Page 27: ...iameter Part Number Description Part Number 7 5 16 Diam L 03107 Thru Deck Foot Assembly B 0021 9 5 16 Diam L 03109 Foot Only B 0021 1 14 5 16 Diam L 03114 Extension Bar B 0021 2 18 5 16 Diam L 03118 Screws B 0021 3 7 3 8 Diam L 03707 Thru Deck Ferrule Holder Part Number 9 3 8 Diam L 03709 3 4 WTD 7 8 Flat B 0060 1 14 3 8 Diam L 03714 3 4 Flat B 0060 2 18 3 8 Diam L 03718 5 8 Flat B 0060 3 24 3 8 D...

Page 28: ...28 TRU WELD Equipment Company 6400 N Honeytown Road Smithville Ohio 44677 330 725 7744 Phone 330 669 2473 Fax TWE tfpcorp com http truweldstudwelding com ...

Reviews: