DISASSEMBLY FOR THE INSPECTION OF THE COUNTER-BLADE
It is imperative to remove the ignition key before this type of servicing
.
-Remove the two attachment bolts (diam.10)
(1)
and the two safety bolts
(2)
(diam.8) at
each end of the counter-blade.
-Drive the blade out by sliding it in its housing to either side. If the edge is worn out remove
the counter-blade from its housing and remount it by shifting it by a quarter turn so that a
new edge is facing the blades.
(Each of the four edges can be used)
-Reinstall the two bolts
(