59
5. GAP AND BLACK MARK SENSOR SELECTION
Gap Sensor selection
Default setting. No extra action necessary.
If you want to change sensor type from black mark sensor to gap sensor,
please do printer initialization (refer to Initialization section).
Black Mark Sensor
Start Label View XLT+ or Nice Label LE software.
Set label side in the software and select black mark sensor as sensor type.
Install label media with black mark or hole for registration.
Print one label to switch sensor from gap to black mark sensor.
Remember, always do sensor calibration after sensor selection (refer to
Gap and
Black Mark Sensor Calibration section).
6. BIOS Update
If printer BIOS update is required, please do the following steps.
Update the BIOS file and reset the printer.
Update File
1. Make sure the printer is at ready status and the LED is solid
green
.
2. Copy the BIOS file to printer parallel port by the following command at
MS-DOS prompt mode.
C:\>COPY TTP-245P.NEW /B LPT1
<Enter>
3. During BIOS updating process, the LED will blink
red
and
orange
alternately.
When BIOS update is completed, printer will reset automatically and LED will
become
solid green
.
Summary of Contents for TTP-245 Plus