background image

 

 

R e a d e r ’ s   C o m m e n t s  

Please help us improve our manuals by completing and returning this questionnaire to the address listed in the 
“About This Manual” section. Feel free to attach a separate sheet of comments. 
 

Manual Title  

Model 9302 Atomizer                                                      

P/N

 1990142 

 
1.  Was the manual easy to understand and use? 

 

 Yes            

 No 

 

Please identify any problem area(s)  _________________________________________________________ 

 

  _____________________________________________________________________________________  

 

  _____________________________________________________________________________________  

2.  Was there any incorrect or missing information? (please explain)  __________________________________  

 

  _____________________________________________________________________________________  

 

  _____________________________________________________________________________________  

3. Please rate the manual according to the following features:

 

 

 

Good 

Adequate 

Poor 

 

Readability 

 

 

 

 

Accuracy  

 

 

 

 

Completeness (is everything there?)  

 

 

 

 

Organization (finding what you need) 

 

 

 

 

Quality and number of illustrations  

 

 

 

 

Quality and number of examples  

 

 

 

 

Comments:  ____________________________________________________________________________  

 

  _____________________________________________________________________________________  

 

  _____________________________________________________________________________________  

4.  Which part(s) of this manual did you find most helpful?  __________________________________________  

 

  _____________________________________________________________________________________  

 

  _____________________________________________________________________________________  

5.  Rate your level of experience with the product: 

 

 Beginning  

 Intermediate  

 Expert  

6.  Please provide us with the following information: 

 

Name  _________________________________    Address ______________________________________  

 

Title   __________________________________     

 ______________________________________  

 

Company  ______________________________     

 ______________________________________  

Summary of Contents for 9302

Page 1: ...SINGLE JET ATOMIZER MODEL 9302 OWNER S MANUAL P N 1990142 REVISION H AUGUST 2015 ...

Page 2: ......

Page 3: ...ory The following is a manual history of the Model 9302 Single Jet Atomizer manual part number 1990142 Revision Date A 1988 B May 1989 C January 1994 D May 1996 E August 1999 F September 2000 G July 2010 H August 2015 ...

Page 4: ...ty in connection with goods which are incorporated into other products or equipment or which are modified by any person other than Seller The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE WITH RESPECT TO SELLER S BREACH OF THE IMPLIED WARRANTY AGAINST INF...

Page 5: ...Getting Help vi Submitting Comments vi S e c t i o n s Description 1 Operation 1 Generating Water Droplets 2 Generating Salt or Sugar Particles 2 Dispersing Polystyrene Latex Particles 2 Generating Oil Droplets 2 Adjusting the Dilution Air 3 Maintenance and Troubleshooting 3 ...

Page 6: ...ne 1 800 874 2811 USA or 651 490 2811 E mail Address fluid tsi com S u b m i t t i n g C o m m e n t s TSI values your comments and suggestions on this manual Please use the comment sheet on the last page of this manual to send us your opinion on the manual s usability to suggest specific improvements or to report any technical errors If the comment sheet has already been used mail or fax your com...

Page 7: ... checkout direct the atomizer s output tube at the point of beam crossing Adjust the height of the output tube by loosening the hex nut and shifting the tube up or down The Atomizer is designed primarily for LV system checkout and should not be used to feed aerosols into a system under pressure O p e r a t i o n Connect the inch dimeter 6 35 mm compressed air hose to your laboratory air supply Fil...

Page 8: ...he water from the droplets The resultant particle size depends on the concentration of the solute in the solution Dispersing Polystyrene Latex Particles A common method of generating monodisperse aerosols is to atomize a hydrosol that contains monodisperse particles For this application add a drop of monodisperse particles to one liter of distilled water in the reservoir Such a large dilution is n...

Page 9: ...ough adjustment screw is factory set to provide no dilution air To change this setting follow these steps 1 Remove the plastic reservoir bowl from the bottom of the Atomizer 2 Located along the outside diameter of the black aluminum cylinder attached to the plastic cap is a no 10 32 setscrew Turn it counterclockwise to open the orifice for dilution Since slight rotation increases the dilution air ...

Page 10: ......

Page 11: ...g features Good Adequate Poor Readability Accuracy Completeness is everything there Organization finding what you need Quality and number of illustrations Quality and number of examples Comments ____________________________________________________________________________ _____________________________________________________________________________________ __________________________________________...

Page 12: ......

Page 13: ... more information USA Tel 1 800 874 2811 UK Tel 44 149 4 459200 France Tel 33 1 41 19 21 99 Germany Tel 49 241 523030 India Tel 91 80 67877200 China Tel 86 10 8219 7688 Singapore Tel 65 6595 6388 P N 1990142 Rev H 2015 TSI Incorporated Printed in U S A ...