CALIBRATIONS / 99
6011258 Rev C
NUMBER (#) METER REVS
The number of revolutions the meter turns during the calibration.
This will constitute the length of the test. The higher the number,
the more accurate the calibration.
NOTE
If performing a Spreader Calibration on a box type drill, catch
the output of a few seed meters, average the weight measured
from these meters, and multiply this average weight by the
total number of meters on the drill. Enter this weight for the
Amount Dispensed value.
PULSE COUNT
A pulse count that is produced from the feedback sensor. This
number is informational only.
NEW SPREADER CONSTANT
After the spreader calibration is performed and the amount is
entered, press the
SAVE
button to accept the new constant.
AMOUNT DISPENSED
Enter the amount (Lbs/Kg) dispensed after performing the
spreader constant calibration. The amount dispensed number
is used with pulse count and density to calculate the new
spreader constant.
SHAFT TURN
The
SHAFT TURN
button turns the shaft one (1) gear revolution
and fills the seed meter for instant seed flow when the control is
turned on.
The meter should be full of material before the calibration
is started.
LIQUID FLOW CALIBRATION
Performing a Limit Output, Valve Calibration, and K-Factor
Calibration are recommended for a Liquid Flow control
channel type.
PERFORM A VALVE CALIBRATION
Follow valve calibration steps 1-10 listed in planter and granular
control valve calibration section.