OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
SECTION LINKING / 109
6011258 Rev C
SECTION LINKING
Section Linking groups sections in a series or in parallel to other
sectio
ns in the system so that these ‘linked’ groups turn on or off
simultaneously at the Work Screen.
Sections are commonly used as a channel (swath-by-drive),
individual, or series of rows commanded as a single section
(clutch control).
Subordinate sections turn off when all their assigned master
sections are off at the same time. Subordinates have no control
over the master sections.
TO LINK SECTIONS:
1. Press the
SECTION LINKING
button.
2. At the Section Linking screen, press the
ADD
button.
3. Press the Master selection box and select the Master control
type to turn on/off sections as clutch, liquid, channel, or IRC.
4. Press the Subordinate selection box and select the
secondary auxiliary to the Master.
5. Assign each section controlled by the Master to the
appropriate channel.
6. Assign each section of the subordinate module controlled by
the Master.
7. After all sections and channels are linked, press the
Back button.
-
The Section Linking screen is now populated with all of
the master/subordinate linkages.
8. Press a specific section linking item and press the
EDIT
button to make changes.
9. Press a specific section linking item and press the
REMOVE
button to delete a link.
10. Press the Down Arrow button to view additional section
linking items.
IMPORTANT
Refer to the Task Controller screen and/or the Channel
Linking screens for more refined settings that are beyond