OPERATOR’S MANUAL
118 /
SENSOR SETUP
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
SENSOR SETUP
Sensor setup assigns up to 196 sensors to rows, selection of the
row type (population/blockage), and assignment of operations to
a module type. If no rows are configured, population monitoring
cannot occur.
SENSOR CONFIGURATION
REQUIREMENTS:
An Operation and its channels must have continuous
row numbers.
A section must have continuous row numbers.
Inputs on a module must start at input 1 and sequence up
a number continuously with no skipped inputs.
A row sensor may not be assigned to more than
one Operation.
If a row has multiple sensors, the sensors on that row cannot
share Operations.
The lowest module address must represent the module
closest to the left side (row 1) of the system. The highest
module address must represent the module closest to the
right side (number of configured rows) of the system.
A module does not have to use all row sensors available
to it.
The operation number assigned to a sensor determines what
is measured. For example, assigning a blockage sensor to
a fertilizer operation or a seed sensor assigned to a
population operation.
Figure 84
Correct Sensor Connections to Module