OPERATOR’S MANUAL
128 / GROUND SPEED SETUP
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
MAIN GROUND SPEED CONSTANT
Represents the pulse count produced by the ground speed
sensor over a
400’ distance. A ground speed calibration is
recommended to obtain the ground speed constant. Refer to the
Calibration section for additional information.
Using a single source radar assumes all rows are moving at the
single speed provided by the tractor speed sensor.
SHUTOFF SPEED
Indicates the minimum ground speed allowed before the system
shuts off all control channels.
MINIMUM OVERRIDE
Minimum override takes over when actual ground speed is below
the designated value. The control operates at this speed until
actual ground speed rises above the minimum override speed or
the actual speed drops below the shutoff speed. The Minimum
Override speed has a background color of black and appears in
the ground speed location on the Work Screen.
NOTE
Minimum override and Master Switch Timeout features will not
display on the Ground Speed setup screen when only Monitor
Type channels are configured.
Figure 93
Minimum Override