GROUND SPEED SETUP / 129
6011258 Rev C
MASTER SW TIMEOUT
Determines the length of time before the system disables the
operate function after ground speed is 0 (zero) if the master
switch remains in the ON position. After the delay time elapses,
an alarm is issued stating that the master switch must be toggled
OFF/ON before the system will restart.
GROUND FAIL ALARM DELAY
Determines the length of time after the ground speed goes to
zero and seed flow continues before the alarm sounds. This
alarm only applies when Monitor Type control channels are
configured.
IMPLEMENT SPEED
A harness is required for this feature and is an input that is
connected to the sensor that senses the implement speed,
i.e. tone wheel with digital proximity sensor. If enabled, the
frequency detected on this input must be above the frequency
threshold before channels will run. Implement Speed must be
enabled when the
MASTER SWITCH
button is not used.
GROUND SPEED CALIBRATION
Ground speed is the rate in MPH (Kph) as measured by the
ground speed sensor. The number reflects the number of pulses
generated by the ground speed sensor while traveling a distance
of 400 feet (100 meters).
IMPORTANT
Performing a ground speed calibration directly influences
population, area accumulation, and application rate
control and is required for digital frequency, reluctance
frequency and IRC.