OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
ACCESSORY SENSORS / 137
6011258 Rev C
RPM CONSTANT
Enter the number of pulses per shaft revolution. If the sensor is
mounted directly to the shaft, the value to enter is the number of
pulses generated by the sensor per revolution of the shaft itself.
If the sensor is mounted elsewhere, a gear or sprocket ratio must
be calculated and entered into the RPM constant.
RPM FILTER
Enter a value that filters the signal out of the RPM sensor.
Typically no filtering is required so the standard value is set at
0%. If the RPM readout on the Work Screen is oscillating in
excess of 10%, increasing the filter value will filter the signal to
reduce the oscillation. For a true RPM value this number should
be set to 0%.
DIGITAL SENSOR SETUP
Figure 100
Digital Sensor Setup
SENSOR NAME
Pressing the Sensor Name field at the top right can change the
desired name for the sensor.