OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
BOUT MARKERS /
139
6011258 Rev C
BOUT MARKERS
BOUT MARKER SETUP
Bout Marker output control can be enabled by selecting Enabled
in the Marker Control Dropdown.
Checking Up for Marker Feedback enables sensors on the left
and right that activate when the respective marker is in the
“Up” position.
Checking Down for Marker Feedback enables sensors on the
left and right that activate when the respective marker is in the
“Down” position.
Table 6. Proximity Sensor States with only Bout Marker Up
Sensors Enabled
NOTE
Because this sensor is detecting the Up condition, if the target
is sensed then the sensed state is Up.
Target
Up Sensor State
Feedback Sensed State
Not Present
LO
Down
Present
HI
Up
Table 7. Proximity Sensor States with only Bout Marker
Down Sensors Enabled
NOTE
Because this sensor is detecting the Down condition, if the
target is sensed then the sensed state is Down.
Target
Down Sensor State
Feedback Sensed State
Not Present
LO
Up
Present
HI
Down
NOTE
Because both an Up and a Down sensor are present, the
cases where both sensors do not detect targets (moving) and
where both sensors do sense targets (error) can be handled. If
only one sensor senses the target then the Sensed State
follows the above cases.