OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
CUSTOMIZING THE WORK SCREEN / 149
6011258 Rev C
QUALITY BAR GRAPH INSTRUMENT
This instrument displays the amount of spacing between each
seed while planting that provides a comparison of row-to-row
meter performance. Ideal conditions are equal spacing between
each seed (100%). As spacing becomes less uniform and more
random, the spacing quality percentage decreases and falls
below 100%. Multiple Quality bar graphs instruments can be
added with different settings per bar graph.
Seed shape, meter type, meter settings, seeding rate, seed bed
preparation and vehicle speed are all factors that can affect
overall spacing quality.
Width
This instrument selects the width of the bar graphs as either
narrow or medium. The wider bar graphs may not all appear on
the first screen if a larger number of rows are monitored. 2x1 (fits
6 wide rows, 12 medium rows, or 24 narrow rows) and 4x1 (fits
12 wide rows, 24 medium rows or 48 narrow rows).
Row Scan
This instrument scans through rows at a fast or slow rate. After
the last row displays, the scan rows will re-sequence beginning
with the first active row.
Operations
This instrument selects the operations to monitor on the
Work Screen.
Spacing Variance
This instrument sets the user-defined percentage to set the bar
graph range for spacing quality. The bottom of the bargraph will
correspond to the user set Spacing Variance subtracted from
100%. A spacing variance of 10% will result in graphs that show
quality levels that range from 90% to 100%.
Bar Graph Size
This instrument sets the bar graph size as 2x1 or 4x1 column.
Row Scan
This instrument scans through rows at a fast or slow rate. After
the last row displays, the scan rows will re-sequence beginning
with the first active row.
Operations
This instrument selects the operations to monitor on the
Work Screen.