OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
OPERATION / 163
6011258 Rev C
Figure 123
Reading the Control Channel
CONTROL CHANNEL ADJUSTMENT
Control channels can be adjusted in Work Mode by selecting
the channel on screen (Figure 122). A channel can be adjusted
as follows:
Active channel can be set to ON or OFF by selecting the
On/Off Channel button.
Target rates can be adjusted by using the Inc/Dec buttons
and the
RESET
Target button.
INCREMENT
Increases the active channel’s target rate by the amount
specified in the Inc/Dec % or rate table setup for that material.
Increment can be pressed several times to increase the target
rate by the specified amount for every actuation, until the
maximum rate value or preset value is reached. The active
channel/material is displayed in the button text.
DECREMENT
Decreases the active channel’s target rate by the amount
specified in the Inc/Dec % or rate table setup for that material.
Decrement can be pressed several times to reduce the target
rate by the specified amount for every actuation, until the
minimum rate value or preset value is reached. The active
channel/material is displayed in the button text.
INC/DEC RESET TO TARGET
Returns the active channel to the original material target rate.
This button is only available for channels that are active and
have had the target rate adjusted using the Increment or
Decrement buttons in Inc/Dec % mode.