OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
SYSTEM TEST / 185
6011258 Rev C
ROW
The active row viewed on the system. The row that is set here is
the row that reports back a seed count in the Test Seed Count
value. The operator can change the row # to get performance of
all rows during the continuous test to see row-to-row variability.
TEST TARGET POPULATION
The seed rate at which the test is performed. This value is the
current target rate and is automatically populated.
TEST SEED COUNT
The seed count reported back on the specified row set in the row
data item and is automatically populated.
NOTE
The Test Seed Count automatically resets whenever a new
continuous test is performed.
5 REV TEST
NOTE
Refer to the System Tests section for using a remote test
switch during a 5 Rev Test operation.
5 Rev Test checks the seed meters for accuracy. When started,
the test runs the control for five revolutions of the seed meters
then shuts down. The seed count can then be correlated on a
row versus the seed count actually dispensed by the meter. A
remote test switch is recommended to perform this test. The
values entered do not affect any other setup values that have
previously been tested.
TO PERFORM THE 5 REV TEST:
1. At the Control screen, select the appropriate channel for the
test.
2. Press the
EDIT
button.
3. Press the
5 REV
button.
4. The following parameters must be entered to perform a
5 Rev Test.
-
Test Ground Speed
-
Row
5. Press the
START
button. The test runs for 5 revolutions
then stops.