OPERATOR’S MANUAL
193 / FACTORY RESET
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
FACTORY RESET (USER LEVEL 3)
Level 3 Users have access to restore system settings to:
FACTORY DEFAULTS - restores configuration files to
factory defaults.
OVERWRITE DEFAULTS - configuration files set by the
user that overwrites factory defaults.
CAUTION
Performing a factory reset should be completed by an
authorized service technician. Restoring or overwriting
current configuration files removes the user-defined
configuration settings. User-defined configuration files
can be exported to a USB memory device for importing a
later time, if desired.
TO RESET MEMORY:
1. Press the
FACTORY RESET
button.
2. Select the button type to Reset to Defaults.
3. Press the Checkmark button to begin system reset.
-
Press the Cancel ‘
X
’ button to cancel reset.
TO CHANGE DEFAULTS:
1. Press the
FACTORY RESET
button.
2. Press Replace Defaults or Factory Defaults.
-
Replace Defaults overwrites the system defaults to the
current system configuration.
-
Factory Defaults sets the system defaults to the defaults
programmed from the factory.
3. Press the Checkmark button to begin system reset.
-
Press the Cancel ‘
X
’ button to cancel reset.
Figure 150
Factory Reset Screen