DIAGNOSTICS / 197
6011258 Rev C
SETPOINT
Channel Setpoint is calculated by the system displaying the
expected feedback frequency of the application rate sensor or
flow meter used for that channel’s feedback.
PWM
The Channel PWM value is the current pulse width modulation
(PWM) output drive signal to the solenoid valve. The higher the
number, the further the valve opens.
ACTUAL RATE
The Channel Actual Rate value is the current channel’s actual
controlled rate with the system active.
ACTUAL SPEED
The channel’s actual RPM or flow rate.
FEEDBACK FREQUENCY
Feedback frequency is the c
urrent channel’s feedback frequency
of the application rate sensor or flow meter used for that
channel’s feedback.
PULSE COUNT
The Channel Pulse Count value is the accumulated pulse count
detected from the channel feedback sensor. This value may be
reset by the operator by pressing the
Reset Channel Pulse
Count
button.
FREQ GSPD
Ground Speed Frequency is the feedback frequency of the
ground speed sensor. Ground Speed Frequency is only shown
when using Digital Frequency or Reluctance Frequency settings
for Ground Speed.
NOTE
If the values are reversed and the value displays a “lowered”
when the implement is raised, the wiring for the implement
switch will need to be reversed so that an accurate readout is
achieved.
IO IMP LIFT
The IO Implement Lift value displays the current state of the
implement status switch. This text states “lowered” when the
implement is down. The text states “raised” when the implement
is raised.