OPERATO
R’S MANUAL
16 / COMPONENT INSTALLATION
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
When connecting seed sensors to the modules, the following
requirements must be observed:
All seed sensors installed must be connected to the seed
sensor harness SEQUENTIALLY starting with the Row 1
input. In the event that not all row inputs on the module are
used, the unused inputs must be the last inputs on that
module.
If the module has multiple sensors for the same row, all
sensors assigned to the same channel must be sequential.
Figure 13
Correct Seed Sensor Module Connection