OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
TROUBLESHOOTING AND ALARM CODES / 205
6011258 Rev C
207
Channel Unstable Alarm
Control channel is unstable at the current
target rate.
1. Incorrect channel settings.
2. Incorrect feedback sensor installation.
3. Defective feedback sensor.
1. Verify correct setup constants on the
Channel Configuration screen. Perform a
valve calibration.
2. Verify correct installation of the
feedback sensor.
3. Inspect feedback sensor for damage
or replace.
4. Verify system is stable using Manual
Control Mode.
208
Channel Saturation
Exceeded Alarm
Control cannot obtain the specified rate.
1. Excessive speed.
2. Incorrect channel settings. Desired rate
too high for implement.
3. Target rate too high.
1. Reduce speed.
2. Verify correct setup constants on the
Channel Configuration screen.
3. Perform a valve calibration and a
Calibration constant.
4. Inspect feedback sensor, motor and
harnessing.
5. Reduce target rate.
209
Control High Limit Alarm
Feedback has exceeded the material High
Limit setting.
1. Target Rate too high.
2. Ground speed too low.
1. Reduce speed or Target Rate.
2. Verify material High Limit setting.
3. Review control channel setup.
210
Control Low Limit Alarm
Feedback has dropped below the material
Low Limit setting.
1. Target Rate too low.
2. Ground speed too high.
1. Increase speed or Target Rate.
2. Verify material Low Limit setting.
3. Review control channel setup.
211
All Rows Failed Alarm
Seeding was not detected on any rows.
1. Seed meter drive malfunction.
2. Rows are not assigned to channel and
channels are turned off.
1. Check seeding drive(s).
2. Assign rows to channel.
3. Inspect sensors and harnessing
for damage.
212
Row Failure Alarm
Seed rate has fallen below the row fail rate
setting on the Seed Monitor Setup screen.
1. Seed meter malfunction.
2. Dirty or defective seed sensor.
3. Damaged planter harness.
4. Defective module harness or module.
5. Out of seed.
1. Verify proper planter operation.
2. Inspect seed sensor for dirt or damage.
Replace if necessary.
3. Inspect planter harness for damage.
Repair or replace.
4. Inspect harness and module for damage.
Replace if necessary.
5. Fill with seed.
6. Review material settings.