OPERATOR’S MANUAL
206 / TROUBLESHOOTING AND ALARM CODES
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
ALARM
#
ALARM
PROBABLE CAUSE
CORRECTIVE ACTION
213
High Population Limit
Exceeded Alarm
Seed rate has exceeded the High Alarm
Setting on the Seed Monitor Setup screen.
1.
Seed meter malfunction or
incorrect setup.
2.
Defective seed sensor.
3.
Defective module.
1. Verify proper planter options/setup.
2. Inspect seed sensor for damage.
Replace if necessary.
3. Inspect module for damage. Replace if
necessary.
4. Review material settings.
214
Low Population Limit
Exceeded Alarm
Seed rate has dropped below the Low Pop
Alarm Setting on the Seed Monitor Setup
screen.
1.
Seed meter malfunction or incorrect
setup.
2.
Defective seed sensor.
3.
Defective module.
4.
Running out of seed.
1.
Verify proper planter operation/setup.
2.
Inspect seed sensor for
damage. Replace if necessary.
3.
Inspect module for damage. Replace if
necessary.
4.
Fill with seed.
215
High Pressure Limit
Exceeded Alarm
Sensed pressure exceeds the high alarm
setting on the Pressure Setup screen.
1.
Implement malfunction or
incorrect setup.
2.
Defective pressure sensor.
3.
Defective module.
1.
Verify proper implement
operation/setup.
2.
Inspect pressure sensor for
damage. Replace if necessary.
3.
Inspect module for damage.
Replace if necessary.
216
Low Pressure Limit
Exceeded Alarm
Sensed pressure below the low alarm
setting on the Pressure Setup screen.
1.
Implement malfunction or incorrect setup.
2.
Defective pressure sensor.
3.
Defective module harness or module.
1.
Verify proper implement operation/setup.
2.
Inspect pressure sensor for damage.
Replace if necessary.
3.
Inspect module and/or module harness
for damage. Replace if necessary.
217
Member Module
Detection Alarm
Number of modules detected does not
match the expected modules configured.
1.
Too few modules connect to system.
2.
Too many modules connected to
system.
3.
Defective CAN/module harness.
4.
Blown module harness fuse.
5.
Defective module.
6.
New module has been added
to system.
1.
Verify correct module configuration
setup on the Module Configuration
screen.
2.
Verify correct module configuration
setup on the Module Configuration
screen.
3.
Identify missing module in the Module
Configuration list. Inspect CAN/module
harness of the missing module for
damage. Repair or replace harness.
4.
Inspect module harness fuse of the
identified module. Replace if
necessary.
5.
Identify missing module in the Module
Configuration list. Inspect missing
module for damage or replace.
6.
Verify correct module configuration
setup on the Module Configuration
screen.
218
Accessory Sensor
Detection Alarm
Number of accessory sensors detected
does not match the expected number
configured.
1.
Defective Sensor.
2.
Defective module or damaged
module harness.
3.
Additional sensor detected but not
configured in the Accessory Setup
screen.
1.
Inspect sensor for damage or
replace.
2.
Inspect module and/or module
harness for damage. Replace if
necessary.
3.
Verify correct# ACC setting for