TROUBLESHOOTING AND ALARM CODES / 207
6011258 Rev C
219
Row Sensor Not
Detected Alarm
Number of seed sensors detected does not
match the expected seed sensors
configured.
1.
Incorrect seed row connections.
2.
Additional seed sensor detected.
3.
Incorrect setup.
4.
Defective seed sensor.
5.
Defective module or damaged
module harness.
1.
Inspect seed sensor for damage
or replace.
2.
Inspect module and/or module
harness for damage. Replace if
necessary.
3.
Verify correct # ROWS setting for
each module.
220
Feedback with Control
Off Alarm
Control channel is not running but feedback
was detected.
1.
Improper channel setup.
2.
Defective feedback sensor.
3.
Defective module or damaged
module harness.
1. Inspect feedback sensor, control valve
and harnessing.
2. Verify control channel feedback settings.
3. Verify control channel calibrations.
221
Channel Invalid
State Alarm
The system has encountered a
software error.
1.
Internal system software error.
1. Cycle system power Off/On. If condition
persists, contact your local dealer.
ALARM
#
ALARM
PROBABLE CAUSE
CORRECTIVE ACTION
222
Control Channel Step
Height Error Alarm
Control channel step height cannot be
calculated.
1.
Implement hydraulic system
malfunction.
2.
Defective control valve.
3.
Incorrect feedback sensor installation.
4.
Defective feedback sensor.
5.
Limit Max Output set too low.
1.
Verify implement hydraulic
system operation.
2.
Inspect control valve for
damage. Replace if necessary.
3.
Verify correct installation of the
feedback sensor.
4.
Inspect feedback sensor for
damage or replace.
5.
Set Limit Max Output to a higher
PWM% on the Valve Calibration
screen. Perform a new valve
calibration.
223
Control Channel
Max Feedback
Unreachable Alarm
Control channel maximum feedback cannot
be reached.
1.
Limit Max Output set too low.
2.
Incorrect feedback sensor installation.
3.
Defective feedback sensor.
1.
Set Limit Max Output to a higher level
on the Valve Calibration screen.
Perform a new valve calibration.
2.
Verify correct installation of the
feedback sensor.
3.
Inspect feedback sensor for damage
or replace.
224
No Channel Gain Steps
Calculated Alarm
Control channel gain steps cannot be
calculated.
1.
Implement hydraulic system
malfunction.
2.
Defective control valve.
3.
Incorrect feedback sensor installation.
4.
Defective feedback sensor.
1.
Verify implement hydraulic
system operation.
2.
Inspect control valve for
damage. Replace if necessary.
3.
Verify correct installation of the
feedback sensor.
4.
Inspect feedback sensor for
damage or replace.