OPERATOR’S MANUAL
208 / TROUBLESHOOTING AND ALARM CODES
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
225
Hopper Sensor Low Alarm
The hopper level is low.
1.
Incorrect logic level setting on the
Hopper Setup screen.
2.
Dirty or defective hopper sensor.
3.
Defective module harness or module.
4.
Hopper empty.
1.
Verify correct logic level setting on the
Hopper Setup screen.
2.
Clean/inspect hopper sensor. Replace
if necessary.
3.
Inspect harness and module for
damage. Replace if necessary.
4.
Fill hopper.
226
RPM High Limit Alarm
Sensed RPM exceeds the high alarm
setting on the RPM or Control Setup
screen.
1.
Implement malfunction or
incorrect setup.
2.
Defective RPM sensor.
3.
Defective module.
1.
Verify proper implement
operation/setup.
2.
Inspect RPM sensor for
damage. Replace if necessary.
3.
Inspect module for damage. Replace
if necessary.
227
RPM Low Limit
Exceeded Alarm
Sensed RPM exceeds the low alarm
setting on the RPM or Control Setup
screen.
1.
Implement malfunction or incorrect
setup.
2.
Defective RPM sensor.
3.
Defective module harness or module.
1.
Verify proper implement
operation/setup.
2.
Inspect RPM sensor for
damage. Replace if necessary.
3.
Inspect module for damage. Replace
if necessary.
229
Digital Sensor Alarm
One or more digital sensors have entered
an alarm state.
1.
Incorrect logic level setting on the
Digital Setup screen.
2.
Dirty or defective digital sensor.
3.
Defective module harness or module
4.
Improper control of actuator that uses
digital sensor feedback.
1.
Verify correct logic level setting on the
Hopper Setup screen.
2.
Clean/inspect hopper sensor. Replace
if necessary.
3.
Inspect harness and module for
damage. Replace if necessary.
4.
Inspect connected actuator for
damage.
ALARM
#
ALARM
PROBABLE CAUSE
CORRECTIVE ACTION
232
Control Channel
Shutdown Alarm
RPM has dropped below the disable
control on low alarm setting on the
Accessory Setup screen.
1.
Defective RPM sensor.
2.
Damaged module harness.
3.
Defective module.
4.
Low RPM.
1.
Inspect RPM sensor for damage.
Replace if necessary.
2.
Inspect module harness for damage.
Repair or replace.
3.
Inspect module for damage. Replace
if necessary.
4.
Increase RPM.
235
New Member Module
Detected Alarm
New member module has been found.
1.
Assign sensors to the new module at
the Module Configuration Setup
screen and its position.
236
Intermittent Member
Module Detected Alarm
A member module that had previously
failed communication has come online.
1.
Inspect harness connections to
this module.
237
Product Level Low Alarm
Estimated product level has dropped
below alarm level.
1.
Fill product bin and reset level.
241
Seeding Detected on a
Control Off Row Alarm
Seed rate detected on an off row.
1.
Defective row sensor.
2.
Control shutoff malfunction.
3.
Improper row channel assignment.
1.
Inspect harness and module
for damage.
2.
Check control shutoff.
3.
Verify correct row to control
channel assignment.